Water Body Name: | Las Flores Canyon Creek |
Water Body ID: | CAR4041500020050622193943 |
Water Body Type: | River & Stream |
DECISION ID |
63877 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Alkalinity as CaCO3 |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the OBJECTIVE. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the OBJECTIVE and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85663 | ||||
Pollutant: | Alkalinity as CaCO3 | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Alkalinity as CaCO3. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | All waters shall be maintained free of toxic substances in concentrations which are toxic to, or which produce detrimental physiological responses in, human, plant, animal, or aquatic life (Water Quality Control Plan, Colorado River Basin). | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | The Alkalinity as CaCO3 criteria for the protection of freshwater aquatic life is 20000 ug/L (National Recommended Water Quality Criteria, 2009). | ||||
Guideline Reference: | National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Office of Science and Technology | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63876 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Aluminum |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 1 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 1 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85664 | ||||
Pollutant: | Aluminum | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 1 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceed the criterion for Aluminum, dissolved. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Surface water shall not contain concentrations of chemical constituents in amounts that adversely affect any designated beneficial use. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | The National Recommended Water Quality Critiera for the protection of aquatic life from aluminum is the chronic continuous concentration (expressed as a 4-day average) of 87 ug/L. | ||||
Guideline Reference: | National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Office of Science and Technology | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63868 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Ammonia |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85665 | ||||
Pollutant: | Nitrogen, ammonia (Total Ammonia) | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Ammonia as N, Total. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Surface water shall not contain concentrations of chemical constituents in amounts that adversely affect any designated beneficial use. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | Aquatic Life Ambient Water Quality Criteria for Ammonia ? Freshwater (USEPA 2013): the 30-day rolling average concentration (criterion continuous concentration or CCC) of total ammonia nitrogen(in mg TAN/L) in freshwater are not to be exceeded more than once every three years on average. The CCC values are based on pH and temperature. The CCC formula is found on page 46 and the table of CCC values is on page 49. | ||||
Guideline Reference: | Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013 | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63825 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Arsenic |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85666 | ||||
Pollutant: | Arsenic | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Arsenic, dissolved. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | The dissolved arsenic criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater for dissolved arsenic is 0.150 mg/L (California Toxics Rule, 2000). | ||||
Objective/Criterion Reference: | Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63854 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Bifenthrin |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85668 | ||||
Pollutant: | Bifenthrin | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Bifenthrin. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | No individual pesticide or combination of pesticides shall be present in concentrations that adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | UC Davis Aquatic Life Criteria: Aquatic life should not be affected unacceptably if the 4-day average concentration of Bifenthrin does not exceed 0.0006 ug/L. | ||||
Guideline Reference: | Aquatic life water quality criteria derived via the UC Davis method: ll. Pyrethroid insecticides. Reviews of Environmental Contamination and Toxicology 216:51-103. | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63857 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Cadmium |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85684 | ||||
Pollutant: | Cadmium | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Cadmium, dissolved. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63858 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Chromium |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85685 | ||||
Pollutant: | Chromium | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Chromium, dissolved. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63859 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Copper |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85686 | ||||
Pollutant: | Copper | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Copper, dissolved. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63860 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Cyhalothrin, Lambda |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85687 | ||||
Pollutant: | Cyhalothrin, Lambda | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Cyhalothrin, lambda, total. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Surface water shall not contain concentrations of chemical constituents in amounts that adversely affect any designated beneficial use. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | UC Davis Aquatic Life Criteria: Aquatic life should not be affected unacceptably if the 4-day average concentration of Cyhalothrin, lambda, total does not exceed 0.0005 ug/L. | ||||
Guideline Reference: | Aquatic life water quality criteria derived via the UC Davis method: ll. Pyrethroid insecticides. Reviews of Environmental Contamination and Toxicology 216:51-103. | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63861 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Cypermethrin |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85688 | ||||
Pollutant: | Cypermethrin | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Cypermethrin, total. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | All waters shall be maintained free of toxic substances in concentrations which are toxic to, or which produce detrimental physiological responses in, human, plant, animal, or aquatic life. (Basin Plan). | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | The interim freshwater criterion maximum concentration is 0.002 ug/L (DFG 00-6, 2000). | ||||
Guideline Reference: | Sacramento River Water Sampling Data for 303(d) Listing/Delisting Process. Letter W-101-200-000 and data files | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63862 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Deltamethrin |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85689 | ||||
Pollutant: | Deltamethrin | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Deltamethrin. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | No individual pesticide or combination of pesticides shall be present in concentrations that adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | The evaluation guideline for Deltamethrin is the maximum acceptable toxicant concentration (MATC) of 0.02 ug/L. | ||||
Guideline Reference: | OPP Pesticide Ecotoxicity Database. | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63863 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Esfenvalerate/Fenvalerate |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85704 | ||||
Pollutant: | Esfenvalerate/Fenvalerate | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Esfenvalerate/Fenvalerate, total. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | No individual pesticide or combination of pesticides shall be present in concentrations that adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | The evaluation guideline for esfenvalerate/fenvalerate is the median lethal concentration (LC50) of 1.13 ug/L, as determined in a 96 hour toxicity test using the fathead minnow, Pimephales promelas. (USEPA OPP Ecotoxicity database) | ||||
Guideline Reference: | OPP Pesticide Ecotoxicity Database. | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63864 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Fenpropathrin |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85705 | ||||
Pollutant: | Fenpropathrin | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Fenpropathrin. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | No individual pesticide or combination of pesticides shall be present in concentrations that adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | The evaluation guideline for Fenpropathrin is the median lethal concentration (LC50; 2.2 ug/L). | ||||
Guideline Reference: | OPP Pesticide Ecotoxicity Database. | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63865 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Iron |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85706 | ||||
Pollutant: | Iron | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Iron, Dissolved. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, Central Valley Region, Tulare Lake Basin: waters shall not contain chemical constituents in concentrations that adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | National Recommended Water Quality Criteria Continuous Concentrations are intended protect aquatic organisms from chronic exposures (expressed as 4-day average concentration) in freshwater. The evaluation guideline for iron is 1,000 ug/L to protect warm freshwater habitat. | ||||
Guideline Reference: | National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Office of Science and Technology | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63866 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Lead |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85707 | ||||
Pollutant: | Lead | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Lead. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63867 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Nickel |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85708 | ||||
Pollutant: | Nickel | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Nickel, dissolved. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63878 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Oxygen, Dissolved |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the OBJECTIVE. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the OBJECTIVE and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85487 | ||||
Pollutant: | Oxygen, Dissolved | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Oxygen, Dissolved. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | The Water Quality Control Plan for the Los Angeles Region (page 3-11) states that: "The dissolved oxygen content of all surface waters designated as WARM shall not be depressed below 5 mg/L as a result of waste discharges." | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63870 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Permethrin |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 0 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 0 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85488 | ||||
Pollutant: | Permethrin, total | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 0 samples exceed the criterion for Permethrin, Total. One sample was not used in the assessment because the laboratory data reporting limit(s) was above the objective and therefore the results could not be quantified with the level of certainty required by the Listing Policy. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | All waters shall be maintained free of toxic substances in concentrations which are toxic to, or which produce detrimental physiological responses in, human, plant, animal, or aquatic life. (Basin Plan). | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | UC Davis Aquatic Life Criteria: Aquatic life should not be affected unacceptably if the 4-day average concentration of Permethrin; Permethrin, total does not exceed 0.0002 ug/L. | ||||
Guideline Reference: | Aquatic life water quality criteria derived via the UC Davis method: ll. Pyrethroid insecticides. Reviews of Environmental Contamination and Toxicology 216:51-103. | ||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63872 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Selenium |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85505 | ||||
Pollutant: | Selenium | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Selenium, dissolved. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | The selenium criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater is 0.005 mg/L (California Toxics Rule, 2000). | ||||
Objective/Criterion Reference: | Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63873 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Silver |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85506 | ||||
Pollutant: | Silver | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Silver. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
33308 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Sulfates |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | Do Not List on 303(d) list (TMDL required list)(2012) |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence are necessary to assess listing status.
2 lines of evidence are available in the administrative record to assess this pollutant. 1 of the 1 samples exceed the OBJECTIVE. 4 of the 4 samples exceed the OBJECTIVE. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 1 of 1 and 4 of 4 samples exceeded the OBJECTIVE and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be removed from the section 303(d) list because applicable water quality standards for the pollutant are being exceeded. |
|
|||||
LOE ID: | 2243 | ||||
Pollutant: | Sulfates | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Not Recorded | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 4 | ||||
Number of Exceedances: | 4 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Four samples with four exceeding. (SWAMP, 2004). | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | CCR- Title 22 Table 64449-B Secondary Maximum Contaminant Levels of 250 mg/l for Sulfate. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Two stations at Las Flores Canyon Creek Lower: 34.03748 -118.63697 and at
Las Flores Canyon Creek Upper: 34.0448 -118.63866. |
||||
Temporal Representation: | Samples were collected March 2003 through March 2004. | ||||
Environmental Conditions: | Los Angeles County Coastal Streams: 404.15 | ||||
QAPP Information: | SWAMP Quality Assurance Plan | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 85507 | ||||
Pollutant: | Sulfates | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 1 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | The sample collected exceeded the objective. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Table 3-8 states that the Sulfates maximum concentration objective in the Malibu Creek watershed is 500 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The sample was collected from the Las Flores Canyon Random Site 1144 station (404BA1144). | ||||
Temporal Representation: | The sample was collected on 6/10/2008. | ||||
Environmental Conditions: | |||||
QAPP Information: | SWAMP QAPP | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
63879 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Temperature, water |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the OBJECTIVE. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the OBJECTIVE and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85508 | ||||
Pollutant: | Temperature, water | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Water Temperature. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | For waters designated WARM, water temperature shall not be altered by more than 5 deg. F above the natural temperature. At no time shall these WARM-designated waters be raised above 80 deg. F as a result of waste discharges. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63880 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Total Dissolved Solids |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the OBJECTIVE. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the OBJECTIVE and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85509 | ||||
Pollutant: | Total Dissolved Solids | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | The sample collected did not exceed the objective. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Table 3-8 states that the Total Dissolved Solids maximum concentration objective in the Malibu Creek watershed is 2000 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The sample was collected from the Las Flores Canyon Random Site 1144 station (404BA1144). | ||||
Temporal Representation: | The sample was collected on 6/10/2008. | ||||
Environmental Conditions: | |||||
QAPP Information: | SWAMP QAPP | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
63882 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Toxicity |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.6 of the Listing Policy. Under section 3.6 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 1 of 1 sample exceeded the GUIDELINE. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 1 of 1 sample exceeded the GUIDELINE and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85510 | ||||
Pollutant: | Toxicity | ||||
LOE Subgroup: | Toxicity | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 1 | ||||
Data and Information Type: | TOXICITY TESTING | ||||
Data Used to Assess Water Quality: | One sample was collected to evaluate water toxicity. The sample did exhibit significant toxicity. The toxicity test included survival and reproduction of Ceriodaphnia dubia. One sample can have multiple toxicity test results but will be counted only once. One sample is defined as being collected on the same day at the same location with the same lab sample id (if provided). | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in, human, plant, animal, or aquatic life. Region 4 Basin Plan. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | Toxicity is defined as a statistically significant effect in the sample exposure compared to the control using EPA-recommended hypothesis testing. For SWAMP data exceedances are counted with the significant effect code SL. SL is defined as the result being significant compared to the negative control based on a statistical test, less than stated the alpha level, AND less than the evaluation threshold. | ||||
Guideline Reference: | Short-term Methods for Estimating the Chronic Toxicity of Effluents and Receiving Waters to Freshwater Organisms. Fourth Edition. Office of Water, U.S. Environmental Protection Agency. Washington, D.C. EPA-821-R-02-013 | ||||
Spatial Representation: | The sample was collected at station 404BA1144. | ||||
Temporal Representation: | The samples were collected in June 2008. | ||||
Environmental Conditions: | |||||
QAPP Information: | Data quality is good. Data results were recorded in the SWAMP database and followed SWAMP protocols. | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
63874 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Zinc |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
1 line of evidence is available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the CRITERIA. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1 sample exceeded the CRITERIA and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85522 | ||||
Pollutant: | Zinc | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Zinc. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
63881 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | pH |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence are necessary to assess listing status.
3 lines of evidence are available in the administrative record to assess this pollutant. 0 of 1 sample exceeded the OBJECTIVE. 0 of 1 sample exceeded the OBJECTIVE. 0 of 1 sample exceeded the OBJECTIVE. Based on the readily available data and information, the weight of evidence indicates that there is insufficient justification for placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 1, 0 of 1 and 0 of 1 sample exceeded the OBJECTIVE and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 85490 | ||||
Pollutant: | pH | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Non-Contact Recreation | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for pH. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, Los Angeles Basin: the pH for insland surface waters, bays, or estuaries shall not be depressed below 6.5 or raised above 8.5 as a result of waste discharges. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
|
|||||
LOE ID: | 85491 | ||||
Pollutant: | pH | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Water Contact Recreation | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for pH. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, Los Angeles Basin: the pH for insland surface waters, bays, or estuaries shall not be depressed below 6.5 or raised above 8.5 as a result of waste discharges. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
|
|||||
LOE ID: | 85489 | ||||
Pollutant: | pH | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | State Water Board staff assessed SWAMP data for Las Flores Canyon Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for pH. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, Los Angeles Basin: the pH for insland surface waters, bays, or estuaries shall not be depressed below 6.5 or raised above 8.5 as a result of waste discharges. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Data for this line of evidence for Las Flores Canyon Creek was collected at 1 monitoring site [ Las Flores Canyon Random Site 1144 - 404BA1144] | ||||
Temporal Representation: | Data was collected on a single day 6/10/2008. | ||||
Environmental Conditions: | Staff is not aware of any special conditions that might affect interpretation of the data. | ||||
QAPP Information: | The SWAMP QAPP (2008) was followed. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||
DECISION ID |
66224 |
Region 4 |
Las Flores Canyon Creek |
||
Pollutant: | Benthic Community Effects |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Original |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Staff Conclusion: | Benthic Community Effects is being considered for placement on the CWA section 303(d) List under sections 3.9 of the Listing Policy. Under section 3.9, an additional line of evidence associating the Benthic Community Effects with a water or sediment concentration of pollutants is necessary to assess listing status.This site is above the 0.79 threshold, and is therefore meeting the water quality objective for the aquatic life beneficial use.
Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing Benthic Community Effects in this water segment on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. This site is above the 0.79 threshold, and is therefore meeting the water quality objective for the aquatic life beneficial use. This sample size is insufficient to determine with the power and confidence of the Listing Policy if standards are not met. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. The CSCI is applicable statewide, accounts for a much wider range of natural variability, and provides equivalent scoring thresholds in all regions of the state. The CSCI will be used in the future for water quality assessment purposes statewide over the regional indices of biologic integrity (IBIs). |
Regional Board Staff Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
|
|||||
LOE ID: | 95278 | ||||
Pollutant: | Benthic-Macroinvertebrate Bioassessments | ||||
LOE Subgroup: | Population/Community Degradation | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Benthic macroinvertebrate surveys | ||||
Data Used to Assess Water Quality: | The CSCI score for this site is 1.15444968065284. This site is above the 0.79 threshold, and is therefore meeting the water quality objective for the aquatic life beneficial use. | ||||
Data Reference: | RWB4 Stormwater Monitoring Council CY2008 CY2009 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | All waters shall be maintained free of toxic substances in concentrations that are lethal to or that produce significant alterations in population or community ecology or receiving water biota. In addition, the health and life history characteristics of aquatic organisms in waters affected by controllable water quality factors shall not differ significantly from those for the same waters in areas unaffected by controllable water quality factors. | ||||
Objective/Criterion Reference: | Water Quality Control Plan Los Angeles Region R4 Basin Plan | ||||
Evaluation Guideline: | The California Stream Condition Index (CSCI) is a biological scoring tool that helps aquatic resource managers translate complex data about benthic macroinvertebrates found living in a stream into an overall measure of stream health. The CSCI score is calculated by comparing the expected condition with actual (observed) results (Rhen, A.C. et al., 2015). CSCI scores range from 0 (highly degraded) to greater than 1 (equivalent to reference). CSCI scoring of biological condition are as follows (per the scientific paper supporting the development of the CSCI scoring tool): greater than or equal to 0.92 = likely intact condition, 0.91 to 0.80 = possibly altered condition, 0.79 to 0.63 = likely altered condition, less than or equal to 0.62 = very likely altered condition. Sites with scores below 0.79 are considered to have exceeded the water quality objective for the aquatic life beneficial use. | ||||
Guideline Reference: | The California Stream Condition Index (CSCI): A New Statewide Biological Scoring Tool for Assessing the Health of Freshwater Streams. | ||||
Spatial Representation: | The samples were collected from Las Flores Canyon Random Site 1144. | ||||
Temporal Representation: | The sample was collected in June 2008. | ||||
Environmental Conditions: | |||||
QAPP Information: | Samples were collected for the SWAMP RWB4 Stormwater Monitoring Council CY 2008 and 2009 following SWAMP protocols and stored in the SWAMP database. | ||||
QAPP Information Reference(s): | Surface Water Ambient Monitoring Program Quality Assurance Program Plan | ||||