Water Body Name: | Soda Lake |
Water Body ID: | CAL3110005019980805102204 |
Water Body Type: | Saline Lake |
DECISION ID |
5522 |
Region 3 |
Soda Lake |
||
Pollutant: | Ammonia (Unionized) |
Final Listing Decision: | List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | List on 303(d) list (TMDL required list)(2006) |
Revision Status | Original |
Sources: | Source Unknown |
Expected TMDL Completion Date: | 2021 |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the section 303(d) list under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.
One line of evidence is available in the administrative record to assess this pollutant. Three measurements exceed the water quality objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Three of 7 samples exceeded the water quality objective and this exceeds the allowable frequency listed in Table 3.1 of the Listing Policy. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | No new data were assessed for 2008. The decision has not changed. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | After review of the available data and information, SWRCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem. |
USEPA Action (if applicable): | USEPA approved the listing of this water body as a water quality limited segment requiring a TMDL for this pollutant. |
|
|||||
LOE ID: | 698 | ||||
Pollutant: | Ammonia (Unionized) | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 7 | ||||
Number of Exceedances: | 3 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Three out of seven samples exceeded the general water quality objective (CCAMP, 2004; SWAMP, 2004). | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | The discharge of wastes shall not cause concentrations of unionized ammonia (NH3) to exceed 0.025 mg/L (as N) in receiving waters (Region 3 Basin Plan, Section II.A.2. Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries, II.A.2.a. General Objectives, page III-4) | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Samples were collected from two sites. Exceedances were detected in samples collected from both sites. | ||||
Temporal Representation: | Samples were collected from January 2000 to May 2000. | ||||
Environmental Conditions: | The water body is located in the Carrizo Plain hydrologic unit, Carrizo Plain hydrologic subarea. Sites are located at Soda Lake Northeast (311SLE) and Soda Lake Culverts at Seven Mile Road (311SLN). | ||||
QAPP Information: | CCAMP, SWAMP QAPP. | ||||
QAPP Information Reference(s): | |||||