Water Body Name: | San Diego River (Lower) |
Water Body ID: | CAR9071100020011025101606 |
Water Body Type: | River & Stream |
DECISION ID |
6514 |
Region 9 |
San Diego River (Lower) |
||
Pollutant: | Fecal Coliform |
Final Listing Decision: | Do Not Delist from 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | List on 303(d) list (TMDL required list)(2006) |
Revision Status | Revised |
Sources: | Nonpoint Source | Point Source | Urban Runoff/Storm Sewers | Wastewater |
Expected TMDL Completion Date: | 2009 |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for removal from the section 303(d) list under section 4.2 of the Listing Policy. Under this section a single line of evidence is necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. Thirteen of 15 of samples exceed the Basin Plan water quality objective for fecal coliform. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against removing this water segment-pollutant combination from the section 303(d) list. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Thirteen of 15 of samples exceed the Basin Plan water quality objective for fecal coliform, and this exceeds the allowable frequency listed in Table 4.2 of the Listing Policy. 4. Pursuant to section 4.11 of the Listing Policy, no additional data and information are available indicating that standards are met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be removed from the section 303(d) list because applicable water quality standards for the pollutant are being exceeded. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board. |
USEPA Action (if applicable): | USEPA approved the listing of this water body as a water quality limited segment requiring a TMDL for this pollutant. |
|
|||||
LOE ID: | 4719 | ||||
Pollutant: | Fecal Coliform | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Not Recorded | ||||
Beneficial Use: | Water Contact Recreation | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | Unspecified--This LOE is a placeholder to support a 303(d) listing decision made prior to 2006. | ||||
Data Reference: | Placeholder reference pre-2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Unspecified | ||||
Objective/Criterion Reference: | Placeholder reference pre-2006 303(d) | ||||
Evaluation Guideline: | Unspecified | ||||
Guideline Reference: | Placeholder reference pre-2006 303(d) | ||||
Spatial Representation: | Unspecified | ||||
Temporal Representation: | Unspecified | ||||
Environmental Conditions: | Unspecified | ||||
QAPP Information: | Unspecified | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 7488 | ||||
Pollutant: | Fecal Coliform | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Water Contact Recreation | ||||
Number of Samples: | 15 | ||||
Number of Exceedances: | 13 | ||||
Data and Information Type: | Fixed station physical/chemical monitoring (conventional pollutants only) | ||||
Data Used to Assess Water Quality: | Thirteen of fifteen samples collected exceed the water quality objective according to results in the San Diego County Municipal Copermittees Urban Runoff Monitoring Report, 2007. Samples were collected one to three times a year from 2001-2006. | ||||
Data Reference: | Urban Runoff Monitoring, Volume 1- Final Report | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | From the Basin Plan, no more than 10% of the samples during any 30-day period for waters designated for contact recreation shall exceed 400 colonies per 100 ml (RWQCB, 2007). | ||||
Objective/Criterion Reference: | Water Quality Control Plan for the San Diego Basin | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Samples were collected at the mass loading station located near the lower boundary of the watershed along a natural channel adjacent to the Fashion Valley Mall in San Diego. | ||||
Temporal Representation: | Samples were collected one to three times a year from 2001-2006. | ||||
Environmental Conditions: | Samples were collected during wet weather. | ||||
QAPP Information: | QA/QC conducted according to Federal Regulations under requirements of a NPDES permit. | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
17921 |
Region 9 |
San Diego River (Lower) |
||
Pollutant: | Manganese |
Final Listing Decision: | List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Sources: | Source Unknown |
Expected TMDL Completion Date: | 2021 |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | Regional Board Conclusion:
This pollutant is being considered for placement on the section 303(d) list under section 3.2 of the Listing Policy. Under section 3.2 one line(s) of evidence is necessary to assess listing status. One line of evidence are available in the administrative record to assess this pollutant. All three of the samples exceed the water quality objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. All three samples exceeded the manganese water quality objective and this sample size is insufficient to determine with the power and confidence of the Listing Policy if standards are not met. A minimum of five samples is needed for application of table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. State Board Review and Conclusion: The Regional Board staff mistakenly assessed manganese as a conventional pollutant and applied table 3.2 of the listing Policy. Manganese is a toxicant and should be assessed using Table 3.1. State Water Board staff has corrected this error and revised the recommendation to List for manganese as follows: This pollutant is being considered for placement on the section 303(d) list under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status. One line of evidence is available in the administrative record to assess this pollutant. Three of the three samples exceed the water quality objective for manganese. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification for placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Three of three samples exceeded the water quality objective for manganese and this exceeds the allowable frequency under Section 3.1 of the Listing Policy. 4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because it cannot be determined if applicable water quality standards are not being exceeded. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | After review of this Regional Board decision, SWRCB staff recommend the following changes to the decision:
The water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards for the pollutant are being exceeded. |
USEPA Action (if applicable): | USEPA approved the listing of this water body as a water quality limited segment requiring a TMDL for this pollutant. |
|
|||||
LOE ID: | 30914 | ||||
Pollutant: | Manganese | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Not Recorded | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 3 | ||||
Number of Exceedances: | 3 | ||||
Data and Information Type: | Fixed station physical/chemical (conventional plus toxic pollutants) | ||||
Data Used to Assess Water Quality: | Five water samples were collected at San Diego River station 907SSDR15 on March, April, June and September 2002, all showed excessive manganese concentrations (SWAMP, 2007). | ||||
Data Reference: | Monitoring data for Region 9 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Inland surface waters shall not contain manganese in excess of the numerical values described in table 3-2. The secondary drinking water standard for manganese is 0.05 mg/l (RWQCB, 2007). | ||||
Objective/Criterion Reference: | Water Quality Control Plan for the San Diego Basin | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Water samples were collected at San Diego River station 907SSDR15; (Latitude 32.7621, Longitude -117.1925). | ||||
Temporal Representation: | Data was collected during the months of May and Sept. 2004, and April and Feb. 2005. | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality control for the chemical analysis portion of this study was conducted in accordance with the California's Surface Water Ambient Monitoring Program. | ||||
QAPP Information Reference(s): | 2002. Quality Assurance Management Plan for the State of California's Surface Water Ambient Monitoring Program. California Department of Fish and Game, Monterey, CA | ||||
DECISION ID |
17603 |
Region 9 |
San Diego River (Lower) |
||
Pollutant: | Toxicity |
Final Listing Decision: | List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Sources: | Nonpoint Source | Other Urban Runoff | Unknown Point Source |
Expected TMDL Completion Date: | 2021 |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the section 303(d) list under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. Five of the 19 samples exceed the water quality objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Five of the 19 samples exceed the toxicity water quality objective and this exceeds the allowable frequency listed in Table 3.1 of the Listing Policy. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board. |
USEPA Action (if applicable): | USEPA approved the listing of this water body as a water quality limited segment requiring a TMDL for this pollutant. |
|
|||||
LOE ID: | 7491 | ||||
Pollutant: | Toxicity | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 4 | ||||
Number of Exceedances: | 3 | ||||
Data and Information Type: | Ambient toxicity testing (chronic) | ||||
Data Used to Assess Water Quality: | Four samples were collected and three samples show significant toxicity levels (SL) as determined by at least one of the following tests: Selenastrum Capicornutum growth test, and Ceriodaphnia dubia survival/reproductive test according to the Surface Water Ambient Monitoring Program, 2007. Samples were collected one to four times a year from 2001-2006. | ||||
Data Reference: | Monitoring data for Region 9 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | From the Basin Plan, all waters shall be free of toxic substances that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life (RWQCB, 2007). | ||||
Objective/Criterion Reference: | Water Quality Control Plan for the San Diego Basin | ||||
Evaluation Guideline: | Waters are considered toxic when samples show significant toxicity levels (SWAMP code SL) when compared to a negative control. Significant toxicity is determined when statistical tests result in an alpha of less than 5% and percent control values less than the evaluation threshold. | ||||
Guideline Reference: | Monitoring data for Region 9 | ||||
Spatial Representation: | Samples were collected at San Diego River 15. | ||||
Temporal Representation: | Samples were collected one to four times a year from 2001-2006. | ||||
Environmental Conditions: | Samples were collected during wet weather. | ||||
QAPP Information: | QA/QC conducted according Surface Ambient Monitoring Program procedures. | ||||
QAPP Information Reference(s): | 2002. Quality Assurance Management Plan for the State of California's Surface Water Ambient Monitoring Program. California Department of Fish and Game, Monterey, CA | ||||
|
|||||
LOE ID: | 25293 | ||||
Pollutant: | Toxicity | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 15 | ||||
Number of Exceedances: | 2 | ||||
Data and Information Type: | Ambient toxicity testing (chronic) | ||||
Data Used to Assess Water Quality: | Two of fifteen samples were found to be toxic as determined by at least one of the following tests: Selenastrum Capicornutum growth test, Ceriodaphnia dubia survival/reproductive test, and Hyalella Azteca growth/survival test according to results in the San Diego County Municipal Copermittees Urban Runoff Monitoring Report, 2007. | ||||
Data Reference: | Monitoring data for Region 9 | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | From the Basin Plan, all waters shall be free of toxic substances that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life (RWQCB, 2007). | ||||
Objective/Criterion Reference: | Water Quality Control Plan for the San Diego Basin | ||||
Evaluation Guideline: | Samples were found to exhibit toxicity when the No Observed Effect Concentration (NOEC) or median lethal concentration (LC50) for any given species was estimated to be less than 100% of the test sample concentration | ||||
Guideline Reference: | Waste Discharge Requirements for Discharges of Urban Runoff From the Municipal Separate Storm Sewer Systems Draining the Watersheds of the County of San Diego, the Incorporated Cities of San Diego, the San Diego Unified Port District, and the San Diego County Regional Airport. Order No. R9-2007-0001 | ||||
Spatial Representation: | Samples were collected at the mass loading station located near the lower boundary of the watershed along a natural channel adjacent to the Fashion Valley Mall in San Diego. Samples were collected one to four times a year from 2001-2006. | ||||
Temporal Representation: | Samples were collected one to four times a year from 2001-2006. | ||||
Environmental Conditions: | Samples were collected during wet weather. | ||||
QAPP Information: | QA/QC conducted according to SWAMP guidelines. | ||||
QAPP Information Reference(s): | 2002. Quality Assurance Management Plan for the State of California's Surface Water Ambient Monitoring Program. California Department of Fish and Game, Monterey, CA | ||||
DECISION ID |
17047 |
Region 9 |
San Diego River (Lower) |
||
Pollutant: | Enterococcus |
Final Listing Decision: | List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Original |
Sources: | Nonpoint Source | Point Source | Urban Runoff/Storm Sewers |
Expected TMDL Completion Date: | 2021 |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the section 303(d) list under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.
One lines of evidence are available in the administrative record to assess this pollutant. Fifteen of 15 of the samples exceed the Basin Plan water quality objective for Enterococcus. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Fifteen of 15 of the samples exceed the Basin Plan water quality objective for Enterococcus, and this exceeds the allowable frequency listed in Table 3.2 of the Listing Policy. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board. |
USEPA Action (if applicable): | USEPA approved the listing of this water body as a water quality limited segment requiring a TMDL for this pollutant. |
|
|||||
LOE ID: | 7487 | ||||
Pollutant: | Enterococcus | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Water Contact Recreation | ||||
Number of Samples: | 15 | ||||
Number of Exceedances: | 15 | ||||
Data and Information Type: | Fixed station physical/chemical monitoring (conventional pollutants only) | ||||
Data Used to Assess Water Quality: | All fifteen samples collected exceed the water quality objective according to results in the San Diego County Municipal Copermittees Urban Runoff Monitoring Report, 2007. Samples were collected one to three times a year from 2001-2006. | ||||
Data Reference: | Urban Runoff Monitoring, Volume 1- Final Report | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | From the Basin Plan, the criteria for enterococcus sets a maximum limit at 61 colonies per 100mL (RWQCB, 2007). | ||||
Objective/Criterion Reference: | Water Quality Control Plan for the San Diego Basin | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Samples were collected at the mass loading station located near the lower boundary of the watershed along a natural channel adjacent to the Fashion Valley Mall in San Diego. | ||||
Temporal Representation: | Samples were collected one to three times a year from 2001-2006. | ||||
Environmental Conditions: | Samples were collected during wet weather. | ||||
QAPP Information: | QA/QC conducted according to Federal Regulations under requirements of a NPDES permit. | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
6519 |
Region 9 |
San Diego River (Lower) |
||
Pollutant: | Low Dissolved Oxygen |
Final Listing Decision: | List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | List on 303(d) list (TMDL required list)(2006) |
Revision Status | Original |
Sources: | Unknown Nonpoint Source | Unknown Point Source | Urban Runoff/Storm Sewers |
Expected TMDL Completion Date: | 2019 |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | 303(d) listing decisions made prior to 2006 were not held in an assessment database. This is a placeholder decision for a 303(d) listing made in a previous assessment cycle. The Regional Boards will update this decision when new data and information become available and are assessed. |
Regional Board Decision Recommendation: | No new data were assessed for 2008. The Regional Board will update this decision when new data and information become available and are assessed. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board. |
USEPA Action (if applicable): | USEPA approved the listing of this water body as a water quality limited segment requiring a TMDL for this pollutant. |
|
|||||
LOE ID: | 4720 | ||||
Pollutant: | Low Dissolved Oxygen | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Not Recorded | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | Unspecified--This LOE is a placeholder to support a 303(d) listing decision made prior to 2006. | ||||
Data Reference: | Placeholder reference pre-2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Unspecified | ||||
Objective/Criterion Reference: | Placeholder reference pre-2006 303(d) | ||||
Evaluation Guideline: | Unspecified | ||||
Guideline Reference: | Placeholder reference pre-2006 303(d) | ||||
Spatial Representation: | Unspecified | ||||
Temporal Representation: | Unspecified | ||||
Environmental Conditions: | Unspecified | ||||
QAPP Information: | Unspecified | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
17046 |
Region 9 |
San Diego River (Lower) |
||
Pollutant: | Nitrogen |
Final Listing Decision: | List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Original |
Sources: | Nonpoint Source | Point Source | Urban Runoff/Storm Sewers |
Expected TMDL Completion Date: | 2021 |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the section 303(d) list under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. Fifteen of 19 of the samples exceed the Basin Plan water quality objective for nitrogen. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Fifteen of 19 of the samples exceed the Basin Plan water quality objective for nitrogen, and this exceeds the allowable frequency listed in Table 3.2 of the Listing Policy. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board. |
USEPA Action (if applicable): | USEPA approved the listing of this water body as a water quality limited segment requiring a TMDL for this pollutant. |
|
|||||
LOE ID: | 7490 | ||||
Pollutant: | Total Nitrogen as N | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 4 | ||||
Number of Exceedances: | 1 | ||||
Data and Information Type: | Fixed station physical/chemical monitoring (conventional pollutants only) | ||||
Data Used to Assess Water Quality: | One of the four samples exceeds water quality objectives according to resullts in the Surface Water Ambient Monitoring Program Annual Progress Report, 2007. Samples were collected on four dates. May 18 and September 13, 2004 and February 28 and April 19, 2005. | ||||
Data Reference: | Monitoring data for Region 9 | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water bodies shall not contain biostimulatory substances in concentrations that promote aquatic growth to the extent that such growths cause nuisance or adversely affect beneficial uses. (RWQCB, 2007)
A desired goal in order to prevent plant nuisance in streams and other flowing waters appears to be 0.1 mg/L total P. These values are not to be exceeded more than 10% of the time unless studies of the specific water body in question clearly show that water quality objective changes are permissible and changes are approved by the Regional Board. Analogous threshold values have not been set for nitrogen compounds; however, natural ratios of nitrogen to phosphorus are to be determined by surveillance and monitoring and upheld. If data are lacking, a ratio of N:P = 10:1, on a weight to weight basis shall be used. (RWQCB, 2007) |
||||
Objective/Criterion Reference: | Water Quality Control Plan for the San Diego Basin | ||||
Evaluation Guideline: | |||||
Guideline Reference: | Water Quality Control Plan for the San Diego Basin | ||||
Spatial Representation: | Samples were collected at the monitoring station San Diego River 15 (station id: 907SSDR15 lat/long: 32.76194/-117.1927), located on the main stem of the San Diego River. | ||||
Temporal Representation: | Samples were collected on four dates. May 18 and September 13, 2004, February 28 and April 19, 2005. | ||||
Environmental Conditions: | The first two sampling events occurred during declining and minimum base flow respectively. The third sample occurred between storm events and the fourth during high base flow. | ||||
QAPP Information: | Quality control for the chemical analysis portion of this study was conducted in accordance with the California's Surface Water Ambient Monitoring Program. | ||||
QAPP Information Reference(s): | 2002. Quality Assurance Management Plan for the State of California's Surface Water Ambient Monitoring Program. California Department of Fish and Game, Monterey, CA | ||||
|
|||||
LOE ID: | 7489 | ||||
Pollutant: | Total Nitrogen as N | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 15 | ||||
Number of Exceedances: | 14 | ||||
Data and Information Type: | Fixed station physical/chemical monitoring (conventional pollutants only) | ||||
Data Used to Assess Water Quality: | Fourteen of fifteen samples collected exceeded the water quality objective according to results in the San Diego County Municipal Copermittees Urban Runoff Monitoring Report, 2007. Samples were collected one to three times a year from 2001-2006. | ||||
Data Reference: | Urban Runoff Monitoring, Volume 1- Final Report | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Water bodies shall not contain biostimulatory substances in concentrations that promote aquatic growth to the extent that such growths cause nuisance or adversely affect beneficial uses. (RWQCB, 2007)
A desired goal in order to prevent plant nuisance in streams and other flowing waters appears to be 0.1 mg/L total P. These values are not to be exceeded more than 10% of the time unless studies of the specific water body in question clearly show that water quality objective changes are permissible and changes are approved by the Regional Board. Analogous threshold values have not been set for nitrogen compounds; however, natural ratios of nitrogen to phosphorus are to be determined by surveillance and monitoring and upheld. If data are lacking, a ratio of N:P = 10:1, on a weight to weight basis shall be used. (RWQCB, 2007) |
||||
Objective/Criterion Reference: | Water Quality Control Plan for the San Diego Basin | ||||
Evaluation Guideline: | |||||
Guideline Reference: | Water Quality Control Plan for the San Diego Basin | ||||
Spatial Representation: | Samples were collected at the mass loading station located near the lower boundary of the watershed along a natural channel adjacent to the Fashion Valley Mall in San Diego. | ||||
Temporal Representation: | Samples were collected one to three times a year from 2001-2006. | ||||
Environmental Conditions: | Samples were collected during wet weather. | ||||
QAPP Information: | QA/QC conducted according to Federal Regulations under requirements of a NPDES permit. | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
6520 |
Region 9 |
San Diego River (Lower) |
||
Pollutant: | Phosphorus |
Final Listing Decision: | List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | List on 303(d) list (TMDL required list)(2006) |
Revision Status | Original |
Sources: | Unknown Nonpoint Source | Unknown Point Source | Urban Runoff/Storm Sewers |
Expected TMDL Completion Date: | 2019 |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | 303(d) listing decisions made prior to 2006 were not held in an assessment database. This is a placeholder decision for a 303(d) listing made in a previous assessment cycle. The Regional Boards will update this decision when new data and information become available and are assessed. |
Regional Board Decision Recommendation: | No new data were assessed for 2008. The Regional Board will update this decision when new data and information become available and are assessed. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board. |
USEPA Action (if applicable): | USEPA approved the listing of this water body as a water quality limited segment requiring a TMDL for this pollutant. |
|
|||||
LOE ID: | 4721 | ||||
Pollutant: | Phosphorus | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Not Recorded | ||||
Beneficial Use: | Warm Freshwater Habitat | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | Unspecified--This LOE is a placeholder to support a 303(d) listing decision made prior to 2006. | ||||
Data Reference: | Placeholder reference pre-2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Unspecified | ||||
Objective/Criterion Reference: | Placeholder reference pre-2006 303(d) | ||||
Evaluation Guideline: | Unspecified | ||||
Guideline Reference: | Placeholder reference pre-2006 303(d) | ||||
Spatial Representation: | Unspecified | ||||
Temporal Representation: | Unspecified | ||||
Environmental Conditions: | Unspecified | ||||
QAPP Information: | Unspecified | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
6522 |
Region 9 |
San Diego River (Lower) |
||
Pollutant: | Total Dissolved Solids |
Final Listing Decision: | List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | List on 303(d) list (TMDL required list)(2006) |
Revision Status | Original |
Sources: | Flow Alteration/Regulation/Modification | Natural Sources | Unknown Nonpoint Source | Unknown Point Source | Urban Runoff/Storm Sewers |
Expected TMDL Completion Date: | 2019 |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | 303(d) listing decisions made prior to 2006 were not held in an assessment database. This is a placeholder decision for a 303(d) listing made in a previous assessment cycle. The Regional Boards will update this decision when new data and information become available and are assessed. |
Regional Board Decision Recommendation: | No new data were assessed for 2008. The Regional Board will update this decision when new data and information become available and are assessed. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board. |
USEPA Action (if applicable): | USEPA approved the listing of this water body as a water quality limited segment requiring a TMDL for this pollutant. |
|
|||||
LOE ID: | 4722 | ||||
Pollutant: | Total Dissolved Solids | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Not Recorded | ||||
Beneficial Use: | Agricultural Supply | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | Unspecified--This LOE is a placeholder to support a 303(d) listing decision made prior to 2006. | ||||
Data Reference: | Placeholder reference pre-2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Unspecified | ||||
Objective/Criterion Reference: | Placeholder reference pre-2006 303(d) | ||||
Evaluation Guideline: | Unspecified | ||||
Guideline Reference: | Placeholder reference pre-2006 303(d) | ||||
Spatial Representation: | Unspecified | ||||
Temporal Representation: | Unspecified | ||||
Environmental Conditions: | Unspecified | ||||
QAPP Information: | Unspecified | ||||
QAPP Information Reference(s): | |||||