Final California 2018 Integrated Report (303(d) List/305(b) Report)

Supporting Information

Regional Board 9 - San Diego Region

Water Body Name: Buena Creek
Water Body ID: CAR9043200020050630113820
Water Body Type: River & Stream
 
DECISION ID
77492
Region 9     
Buena Creek
 
Pollutant: Phosphate
Final Listing Decision: Delist from 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Delist from 303(d) list (TMDL required list)(2016)
Revision Status Original
Reason for Delisting: Flaws in original listing
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: The decision has not changed from the previous listing cycle. No new data were assessed for the current listing cycle. Therefore, the previous conclusion remains unchanged, and is as follows:

Regional Board Conclusion:
This pollutant is being considered for placement on the section 303(d) list under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. A large number of samples exceed the water quality phosphate goal of 0.1 mg/L in stream and flowing waters.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Four of 4 samples exceeded the phosphate water quality objective and this exceeds the allowable frequency listed in Table 3.1 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.



State Board Review and Conclusion:
The original listing in 2006 applied Table 3.1 of the Listing Policy to determine if phosphorus should be listed. Table 3.1 is used for toxicants with a minimum sample requirement of 2 samples. However, Region 9 considers phosphorus a conventional pollutant and as such, Table 3.2 should have been applied with a minimum requirement of 5 samples.

There are only 4 samples in the line of evidence and this is insufficient to place the water body-pollutant combination on the section 303(d) list.

Furthermore, the line of evidence used to list this water body was based on phosphorus data and not phosphate data. The appropriate decision should have been for phosphorus.

State Board staff re-evaluated the original listing and recommends to Delist phosphate. Also, in order to correctly track these phosphorus data, these same data have been reassessed under the correct pollutant name "phosphorus" with a Do Not List decision. The revised recommendation for delisting phosphate is as follows:

This pollutant is being considered for removal from the section 303(d) list under section 4 of the Listing Policy. Under this section an existing listing may be removed if the listing was based on faulty data and it is demonstrated that the listing would not have occurred in the absence of such faulty data.

One line of evidence is available in the administrative record to assess this pollutant. Four of 4 samples exceed the water quality goal of 0.1 mg/L for phosphorus in streams and flowing waters.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of removing this water segment-pollutant combination from the section 303(d) list.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Four of 4 samples exceeded the basin plan water quality goal and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy. This pollutant should not have been listed in 2006.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: This is a decision previously approved by the State Water Resources Control Board and the USEPA. No new data were assessed by the Regional Board for the current cycle. The decision has not changed.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 77492, Phosphate
Region 9     
Buena Creek
 
LOE ID: 3188
 
Pollutant: Phosphate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Four water samples, four samples exceeding the basin plan goal (SWAMP, 2004).
Data Reference: Placeholder reference 2006 303(d)
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain biostimulatory substances in concentrations that promote aquatic growth to the extent that such growth causes nuisances or adversely affects beneficial uses. Water Quality Control Plan phosphate goal of 0.1 mg/L in stream and flowing waters.
Objective/Criterion Reference: Placeholder reference 2006 303(d)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: One Station at Buena Creek: 33.17225 -117.20887.
Temporal Representation: Samples were collected from March through September of 2002.
Environmental Conditions: Buena Creek 904.32.
QAPP Information: SWAMP Quality Assurance Plan.
QAPP Information Reference(s):
 
 
DECISION ID
68907
Region 9     
Buena Creek
 
Pollutant: Nitrate and Nitrite
Final Listing Decision: Do Not Delist from 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not Delist from 303(d) list (TMDL required list)(2016)
Revision Status Original
Sources: A Source Unknown
Expected TMDL Completion Date: 2019
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for removal from the CWA section 303(d) List under section 4.1 of the Listing Policy. Under this section a single line of evidence is necessary to assess listing status.

One lines of evidence are available in the administrative record to assess pollutant. Five of 5 samples exceed the criteria.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against removing this water segment-pollutant combination from the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Five of 5 samples exceed the criteria and this exceeds the allowable frequency listed in Table 4.1 of the Listing Policy.
4. Pursuant to section 4.11 of the Listing Policy, no additional data and information are available indicating that standards are met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be removed from the section 303(d) list because applicable water quality standards for the pollutant are being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 68907, Nitrate and Nitrite
Region 9     
Buena Creek
 
LOE ID: 3185
 
Pollutant: Nitrate and Nitrite
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Four of 4 samples exceeded the MCLs (SWAMP, 2004).
Data Reference: Placeholder reference 2006 303(d)
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters designated for use as domestic or municipal supply shall not contain concentrations of nitrate and nitrite as nitrogen in excess of Maximum Contaminant Levels (MCL) set forth in Title 22 of the CCR, Table 64431-A of section 64431.
Objective/Criterion Reference: Placeholder reference 2006 303(d)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: One sample site at Buena Creek: 33.17225 - 117.20887.
Temporal Representation: Samples were collected from March through September of 2002.
Environmental Conditions: Buena Creek 904.32.
QAPP Information: SWAMP Quality Assurance Plan
QAPP Information Reference(s):
 
Line of Evidence (LOE) for Decision ID 68907, Nitrate and Nitrite
Region 9     
Buena Creek
 
LOE ID: 73092
 
Pollutant: Nitrate/Nitrite (Nitrite + Nitrate as N)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceed the criterion for Nitrate/Nitrite as N.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nitrate + nitrite (as N) is 10.0 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected on a single day 9/3/2003.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
69539
Region 9     
Buena Creek
 
Pollutant: Cadmium
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 7 samples exceed the criteria for MUN and 0 of 7 samples exceed the criteria for WARM.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 7 samples exceed the criteria for MUN and 0 of 7 samples exceed the criteria for WARM and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 69539, Cadmium
Region 9     
Buena Creek
 
LOE ID: 73081
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Cadmium.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 69539, Cadmium
Region 9     
Buena Creek
 
LOE ID: 73082
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Cadmium.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for cadmium is 0.005 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
81145
Region 9     
Buena Creek
 
Pollutant: Chlorpyrifos
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 5 samples exceed the criteria for MUN and 0 of 0 samples exceed the criteria for WARM.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 5 samples exceed the criteria for MUN and 0 of 0 samples exceed the criteria for WARM and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 81145, Chlorpyrifos
Region 9     
Buena Creek
 
LOE ID: 73083
 
Pollutant: Chlorpyrifos
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 0 samples exceed the criterion for Chlorpyrifos.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The freshwater criterion continuous concentration to protect aquatic organisms is 0.015 ug/L (Siepmann and Finlayson 2000).
Guideline Reference: Water quality criteria for diazinon and chlorpyrifos. Administrative Report 00-3. Rancho Cordova, CA: Pesticide Investigations Unit, Office of Spills and Response. CA Department of Fish and Game (with minor corrections to significant figures as described in Beaulaurier et al., 2005).
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 81145, Chlorpyrifos
Region 9     
Buena Creek
 
LOE ID: 77986
 
Pollutant: Chlorpyrifos
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 5 samples exceed the criterion for Chlorpyrifos.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The USEPA drinking water health advisory for chlorpyrifos is 2.1 µg/L.
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
81142
Region 9     
Buena Creek
 
Pollutant: Copper
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 7 samples exceed the criteria for MUN and 0 of 7 samples exceed the criteria for WARM.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 7 samples exceed the criteria for MUN and 0 of 7 samples exceed the criteria for WARM and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 81142, Copper
Region 9     
Buena Creek
 
LOE ID: 73084
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Copper.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 81142, Copper
Region 9     
Buena Creek
 
LOE ID: 73085
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Copper.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary MCL for copper is 1.0 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Secondary Maximum Contaminant Levels and Compliance. CCR Title 22 section 64449.
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
76687
Region 9     
Buena Creek
 
Pollutant: Diazinon
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 5 samples exceed the criteria for MUN and 0 of 5 samples exceed the criteria for WARM.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 5 samples exceed the criteria for MUN and 0 of 5 samples exceed the criteria for WARM and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 76687, Diazinon
Region 9     
Buena Creek
 
LOE ID: 77987
 
Pollutant: Diazinon
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 5 samples exceed the criterion for Diazinon.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The USEPA drinking water health advisory for diazinon is 1.4 µg/L.
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 76687, Diazinon
Region 9     
Buena Creek
 
LOE ID: 73086
 
Pollutant: Diazinon
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 5 samples exceed the criterion for Diazinon.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The freshwater chronic value for diazinon is 0.1 ug/L, expressed as a continuous concentration (Finlayson, 2004).
Guideline Reference: Water quality for diazinon. Memorandum to J. Karkoski, Central Valley RWQCB. Rancho Cordova, CA: Pesticide Investigation Unit, CA Department of Fish and Game
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
81143
Region 9     
Buena Creek
 
Pollutant: Lead
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 7 samples exceed the criteria for MUN and 0 of 7 samples exceed the criteria for WARM.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 7 samples exceed the criteria for MUN and 0 of 7 samples exceed the criteria for WARM and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 81143, Lead
Region 9     
Buena Creek
 
LOE ID: 73089
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Lead.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 81143, Lead
Region 9     
Buena Creek
 
LOE ID: 73090
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Lead.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for Lead is 0.015 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
77911
Region 9     
Buena Creek
 
Pollutant: Malathion
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 5 samples exceed the criteria for MUN and 0 of 5 samples exceed the criteria for WARM.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 5 samples exceed the criteria for MUN and 0 of 5 samples exceed the criteria for WARM and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 77911, Malathion
Region 9     
Buena Creek
 
LOE ID: 73091
 
Pollutant: Malathion
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 5 samples exceed the criterion for Malathion.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The USEPA national ambient water quality criteria for freshwater aquatic life instantaneous maximum for malathion is 0.1 µg/L.
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 77911, Malathion
Region 9     
Buena Creek
 
LOE ID: 77988
 
Pollutant: Malathion
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 5 samples exceed the criterion for Malathion.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The USEPA drinking water health advisory for malathion is 100 µg/L.
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
81195
Region 9     
Buena Creek
 
Pollutant: Nitrogen, Nitrite
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

One lines of evidence are available in the administrative record to assess this pollutant. Zero of 2 samples exceed the criteria.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 2 samples exceed the criteria and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 81195, Nitrogen, Nitrite
Region 9     
Buena Creek
 
LOE ID: 73093
 
Pollutant: Nitrogen, Nitrite
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 2
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 2 samples exceed the criterion for Nitrite as N.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nitrite (as N) is 1.0 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 6/30/2003-9/3/2003.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
81196
Region 9     
Buena Creek
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

One lines of evidence are available in the administrative record to assess this pollutant. Zero of 1 sample exceeds the criteria.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 1 sample exceeds the criteria and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 81196, Nitrogen, ammonia (Total Ammonia)
Region 9     
Buena Creek
 
LOE ID: 73080
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Ammonia As N, Total.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Basin Plan: No individual chemical or combination of chemicals shall be present in concentrations that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: EPA's Lifetime Health advisory level for total ammonia is 30.0 mg/L as stated on page 8 of the 2006 edition of the drinking water standards and health advisories. This Advisory Level is defined as "the concentration of a chemical in drinking water that is not expected to cause any adverse noncarcinogenic effects for up to ten days of exposure."
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected on a single day 6/30/2003.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
81144
Region 9     
Buena Creek
 
Pollutant: Zinc
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 7 samples exceed the criteria for MUN and 0 of 7 samples exceed the criteria for WARM.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 7 samples exceed the criteria for MUN and 0 of 7 samples exceed the criteria for WARM and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 81144, Zinc
Region 9     
Buena Creek
 
LOE ID: 73064
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Zinc.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 81144, Zinc
Region 9     
Buena Creek
 
LOE ID: 73063
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Zinc.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual chemical or combination of chemicals shall be present in concentrations that adversely affect beneficial uses. (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The California Secondary MCL for zinc is 5.0 mg/L (Title 22 California Code of Regulations).
Guideline Reference: Secondary Maximum Contaminant Levels and Compliance. CCR Title 22 section 64449.
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
68398
Region 9     
Buena Creek
 
Pollutant: DDT (Dichlorodiphenyltrichloroethane)
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Sources: A Source Unknown
Expected TMDL Completion Date: 2019
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the section 303(d) list under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. A large number of samples exceed the California Toxic Rule: Human Health carcinogenic risk for consumption of water & organisms of 0.00059 µg/L.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Four of 4 samples exceeded the CTR DDT criterion and this exceeds the allowable frequency listed in Table 3.1 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: This is a decision previously approved by the State Water Resources Control Board and the USEPA. No new data were assessed by the Regional Board for the current cycle. The decision has not changed.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 68398, DDT (Dichlorodiphenyltrichloroethane)
Region 9     
Buena Creek
 
LOE ID: 3186
 
Pollutant: DDT (Dichlorodiphenyltrichloroethane)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Four of 4 samples exceeded the CTR criterion (SWAMP, 2004).
Data Reference: Placeholder reference 2006 303(d)
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses.

California Toxic Rule: Human Health carcinogenic risk for consumption of water & organisms, 0.00059 μg/L.
Objective/Criterion Reference: Placeholder reference 2006 303(d)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: One sample site in Buena Creek at 33.17225 - 117.20887.
Temporal Representation: Samples were collected from March through September of 2002.
Environmental Conditions: Buena Creek 904.32
QAPP Information: SWAMP Quality Assurance Plan.
QAPP Information Reference(s):
 
 
DECISION ID
86639
Region 9     
Buena Creek
 
Pollutant: Indicator Bacteria
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Sources: A Source Unknown
Expected TMDL Completion Date: 2029
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

Three lines of evidence are available in the administrative record to assess this pollutant. Data from 2003 to 2009 show that 7 of 8 and 6 of 8 single samples exceed the water quality objectives for single sample maximums of enterococcus and fecal coliform for the protection of REC-1, and 3 of 8 samples exceeded the evaluation guideline for Total Coliform.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Data from 2003 to 2009 show that 7 of 8 and 6 of 8 single samples exceed the water quality objectives for single sample maximums of enterococcus and fecal coliform for the protection of REC-1 and this exceeds the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 86639, Indicator Bacteria
Region 9     
Buena Creek
 
LOE ID: 73088
 
Pollutant: Fecal Coliform
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 8
Number of Exceedances: 6
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 6 of 8 samples exceed the criterion for Coliform, Fecal.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: In waters designated for water contact recreation (REC I), the fecal coliform concentration shall not exceed 400 MPN/100 ml.
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 6/30/2003-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 86639, Indicator Bacteria
Region 9     
Buena Creek
 
LOE ID: 73094
 
Pollutant: Total Coliform
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 8
Number of Exceedances: 3
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 3 of 8 samples exceed the criterion for Coliform, Total.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: All waters shall be maintained free of toxicsubstances in concentrations which are toxic to,or which produce detrimental physiologicalresponses in human, plant, animal, or indigenousaquatic life (Basin Plan).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: In waters designated for water contact recreation (REC I), the total coliform concentration shall not exceed 10000 MPN/100 ml (CDPH 2006).
Guideline Reference: Draft Guidance for Fresh Water Beaches. Last Update: May 8, 2006. Initial Draft: November 1997. California Department of Public Health.
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 6/30/2003-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 86639, Indicator Bacteria
Region 9     
Buena Creek
 
LOE ID: 73087
 
Pollutant: Enterococcus
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 8
Number of Exceedances: 7
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 7 of 8 samples exceed the criterion for Enterococci.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Samples shall not exceed 61 organisms per 100 ml for enterococcus in waters designated for REC I beneficial use (Water Quality Control Plan for the San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 6/30/2003-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
77908
Region 9     
Buena Creek
 
Pollutant: Nitrogen
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Sources: A Source Unknown
Expected TMDL Completion Date: 2023
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the section 303(d) list under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Four of four of the samples exceed the water quality objective for total nitrogen.

According to table 3.1 of the Listing Policy, the minimum sample requirement to assess toxic pollutants is 2.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification for placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Four of four of the samples exceed the water quality objective for total nitrogen. and this exceeds the allowable frequency listed in Table 3.1 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 77908, Nitrogen
Region 9     
Buena Creek
 
LOE ID: 6542
 
Pollutant: Total Nitrogen as N
LOE Subgroup: Pollution
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: Fixed station physical/chemical monitoring (conventional pollutants only)
Data Used to Assess Water Quality: All four samples collected at Buena Creek show excessive nitrogen concentrations according to results in California's Surface Water Ambient Monitoring Program Report, 2007.
Water samples were collected in March, April, June and September 2002.
Data Reference: Water Quality Control Plan for the San Diego Basin
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Water bodies shall not contain biostimulatory substances in concentrations that promote aquatic growth to the extent that such growths cause nuisance or adversely affect beneficial uses (RWQCB, 2007).
A desired goal in order to prevent plant nuisance in streams and other flowing waters appears to be 0.1 mg/L total phosphorus, P. These values are not to be exceeded more than 10% of the time unless studies of the specific water body in question clearly show that water quality objective changes are permissible and changes are approved by the Regional Board. Analogous threshold values have not been set for nitrogen compounds; however, natural ratios of nitrogen to phosphorus are to be determined by surveillance and monitoring and upheld. If data are lacking, a ratio of N:P = 10:1, on a weight to weight basis shall be used (RWQCB, 2007).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference: Water Quality Control Plan for the San Diego Basin
 
Spatial Representation: Water samples were collected at Buena Creek station 904CBBUR1; (Latitude 33.1725, Longitude -117.2082).
Temporal Representation: Water samples were collected in March, April, June and September 2002.
Environmental Conditions:
QAPP Information: Quality control for the chemical analysis portion of this study was conducted in accordance with the California's Surface Water Ambient Monitoring Program.
QAPP Information Reference(s):
 
 
DECISION ID
68969
Region 9     
Buena Creek
 
Pollutant: Phosphorus
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Sources: A Source Unknown
Expected TMDL Completion Date: 2023
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the section 303(d) list under section 3.1 of the Listing Policy. Under this section a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Four of four of samples exceeded the water quality objective.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Four of four samples exceeded the water quality standard for phosphorus and this exceeds the allowable frequency listed in Table 3.1 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 68969, Phosphorus
Region 9     
Buena Creek
 
LOE ID: 6540
 
Pollutant: Phosphorus
LOE Subgroup: Pollution
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: Fixed station physical/chemical monitoring (conventional pollutants only)
Data Used to Assess Water Quality: Four of four samples collected at Buena Creek show excessive phosphorous concentrations according to results in California's Surface Water Ambient Monitoring Program, 2007. Samples were collected in March, April, June and September 2002.
Data Reference: Monitoring data for Region 9
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: From the Basin Plan: For inland surface waters-streams and other flowing waters, with all beneficial uses, the water quality objective for total phosphorus is 0.1 mg/L (RWQCB, 2007).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Water samples were collected at Buena Creek station 904CBBUR1; (Latitude 33.1725, Longitude -117.2082).
Temporal Representation: Samples were collected in March, April, June and September 2002.
Environmental Conditions:
QAPP Information: Quality control for the chemical analysis portion of this study was conducted in accordance with the California's Surface Water Ambient Monitoring Program.
QAPP Information Reference(s):