Draft California 2020 Integrated Report (303(d) List/305(b) Report)

Supporting Information

Regional Board 5 - Central Valley Region

Water Body Name: Terminous Tract Drain, at Hwy 12 (San Joaquin County)
Water Body ID: CAR5440000020101103110608
Water Body Type: River & Stream
 
DECISION ID
119848
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Aldicarb
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119848, Aldicarb
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71224
 
Pollutant: Aldicarb
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Aldicarb.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in concentrations that adversely affect beneficial uses. (Water Quality Control Plan, Central Valley Region, Sacramento River Basin and San Joaquin River Basin)
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: The Department of Public Health archived advisory level for aldicarb is 7 ug/L.
Guideline Reference: CDPH Archived Advisory Levels for Drinking Water. Archived Advisory Levels are currently considered Notification Levels.
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 119848, Aldicarb
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 185996
 
Pollutant: Aldicarb
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 38
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 38 samples exceeded the water quality threshold for Aldicarb.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for aldicarb incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 3 ug/L
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2016-09-20
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119831
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Arsenic
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119831, Arsenic
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 186369
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 46
Number of Exceedances: 2
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 2 of 46 samples exceeded the water quality threshold for Arsenic.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for arsenic incorporated by reference in the Basin Plan is 0.010 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2018-08-21
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
Line of Evidence (LOE) for Decision ID 119831, Arsenic
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71250
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 3
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 3 of 15 samples exceed the criterion for Arsenic.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for arsenic is 0.010 mg/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
119832
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Atrazine
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119832, Atrazine
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 186530
 
Pollutant: Atrazine
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 37
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 37 samples exceeded the water quality threshold for Atrazine.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for atrazine incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.001 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2016-09-20
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
Line of Evidence (LOE) for Decision ID 119832, Atrazine
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71253
 
Pollutant: Atrazine
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Atrazine.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for atrazine is 1 ug/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
119833
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Cadmium
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119833, Cadmium
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71285
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 0 samples exceed the criterion for Cadmium.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for cadmium is 5 ug/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 119833, Cadmium
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 186834
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Cadmium.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for cadmium incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.005 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
Line of Evidence (LOE) for Decision ID 119833, Cadmium
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 186854
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Cadmium.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for cadmium incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.005 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119834
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Carbofuran
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119834, Carbofuran
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71317
 
Pollutant: Carbofuran
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Carbofuran.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for Carbofuran is 18 ug/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 119834, Carbofuran
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 187112
 
Pollutant: Carbofuran
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 38
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 38 samples exceeded the water quality threshold for Carbofuran.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for Carbofuran incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.018 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2016-09-20
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119835
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Copper
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119835, Copper
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 187799
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Copper.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary Maximum Contaminant Level for copper incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 1.0 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
Line of Evidence (LOE) for Decision ID 119835, Copper
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71319
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Copper.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California secondary maximum contaminant level for copper is 1.0 mg/L.
Objective/Criterion Reference: Secondary Maximum Contaminant Levels and Compliance. CCR Title 22 section 64449.
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 119835, Copper
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 187822
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 22
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 22 samples exceeded the water quality threshold for Copper.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary Maximum Contaminant Level for copper incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 1.0 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2016-08-16
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
127068
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: DDD (Dichlorodiphenyldichloroethane)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 127068, DDD (Dichlorodiphenyldichloroethane)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 188070
 
Pollutant: DDD (Dichlorodiphenyldichloroethane)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support, and the results are as follows: 0 of the 0 samples exceeded the evaluation guideline for DDD(p,p'). Although a total of 16 samples were collected, 16 of these samples were not included in the assessment because the laboratory data reporting limit(s) was above the water quality threshold and therefore the results could not be quantified with the level of certainty required by the Listing Policy Section 6.1.5.5.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The DDD(p,p) criteria for the protection of human health from the consumption of water and organisms is 0.00059 ug/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT).
Temporal Representation: Date for this waterbody was collected over the date range 2010-09-07 to 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
127069
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: DDE (Dichlorodiphenyldichloroethylene)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 127069, DDE (Dichlorodiphenyldichloroethylene)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 188144
 
Pollutant: DDE (Dichlorodiphenyldichloroethylene)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support, and the results are as follows: 0 of the 0 samples exceeded the evaluation guideline for DDE(p,p'). Although a total of 16 samples were collected, 16 of these samples were not included in the assessment because the laboratory data reporting limit(s) was above the water quality threshold and therefore the results could not be quantified with the level of certainty required by the Listing Policy Section 6.1.5.5.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The DDE(p,p) criteria for the protection of human health from the consumption of water and organisms is 0.00059 ug/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT).
Temporal Representation: Date for this waterbody was collected over the date range 2010-09-07 to 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
127070
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: DDT (Dichlorodiphenyltrichloroethane)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 127070, DDT (Dichlorodiphenyltrichloroethane)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 188336
 
Pollutant: DDT (Dichlorodiphenyltrichloroethane)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support, and the results are as follows: 0 of the 0 samples exceeded the evaluation guideline for DDT(p,p'). Although a total of 16 samples were collected, 16 of these samples were not included in the assessment because the laboratory data reporting limit(s) was above the water quality threshold and therefore the results could not be quantified with the level of certainty required by the Listing Policy Section 6.1.5.5.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The DDT(p,p) criteria for the protection of human health from the consumption of water and organisms is 0.00059 ug/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT).
Temporal Representation: Date for this waterbody was collected over the date range 2010-09-07 to 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119836
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Dieldrin
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119836, Dieldrin
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 188852
 
Pollutant: Dieldrin
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support, and the results are as follows: 0 of the 0 samples exceeded the evaluation guideline for Dieldrin. Although a total of 16 samples were collected, 16 of these samples were not included in the assessment because the laboratory data reporting limit(s) was above the water quality threshold and therefore the results could not be quantified with the level of certainty required by the Listing Policy Section 6.1.5.5.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Dieldrin criteria for the protection of human health from the consumption of water and organisms is 0.00014 ug/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT).
Temporal Representation: Date for this waterbody was collected over the date range 2010-09-07 to 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
Line of Evidence (LOE) for Decision ID 119836, Dieldrin
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71362
 
Pollutant: Dieldrin
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 0 samples exceed the criterion for Dieldrin.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The criterion for Dieldrin to protect human health from the consumption of water and organisms is 0.00014 ug/L (California Toxics Rule).
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
119837
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Endrin
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119837, Endrin
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71383
 
Pollutant: Endrin
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 23
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 23 samples exceed the criterion for Endrin.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Endrin criterion for the protection of human health from the consumption of water and organisms is 0.76 ug/L. (California Toxics Rule, 2000)
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 119837, Endrin
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 189554
 
Pollutant: Endrin
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Endrin.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Endrin criteria for the protection of human health from the consumption of water and organisms is 0.76 ug/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119838
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Glyphosate
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119838, Glyphosate
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 190265
 
Pollutant: Glyphosate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 20
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 20 samples exceeded the water quality threshold for Glyphosate.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for Glyphosate incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.7 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2016-07-19
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
Line of Evidence (LOE) for Decision ID 119838, Glyphosate
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71404
 
Pollutant: Glyphosate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Glyphosate.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for Glyphosate is 700 ug/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
119839
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Lead
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 119839, Lead
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 190886
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Lead.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water Quality Control Plan, Central Valley Region Sacramento River Basin and San Joaquin River Basin: At a minimum, water designated for use as MUN shall not contain lead in excess of 0.015 mg/l.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
Line of Evidence (LOE) for Decision ID 119839, Lead
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 190931
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Lead.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water Quality Control Plan, Central Valley Region Sacramento River Basin and San Joaquin River Basin: At a minimum, water designated for use as MUN shall not contain lead in excess of 0.015 mg/l.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119840
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Methoxychlor
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119840, Methoxychlor
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71453
 
Pollutant: Methoxychlor
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 23
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 23 samples exceed the criterion for Methoxychlor.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for Methoxychlor, 30 ug/L, is incorporated by reference into the (Water Quality Control Plan, Central Valley Region, Sacramento and San Joaquin Basins).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 119840, Methoxychlor
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 191424
 
Pollutant: Methoxychlor
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Methoxychlor.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for Methoxychlor incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.03 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119841
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Nickel
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119841, Nickel
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71476
 
Pollutant: Nickel
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Nickel.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for nickel is 0.1 mg/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 119841, Nickel
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 191734
 
Pollutant: Nickel
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Nickel.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for nickel incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.1 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
Line of Evidence (LOE) for Decision ID 119841, Nickel
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 191891
 
Pollutant: Nickel
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Nickel.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for nickel incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.1 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119842
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Nitrate/Nitrite (Nitrite + Nitrate as N)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
 
Line of Evidence (LOE) for Decision ID 119842, Nitrate/Nitrite (Nitrite + Nitrate as N)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71477
 
Pollutant: Nitrate/Nitrite (Nitrite + Nitrate as N)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Nitrate/Nitrite as N.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for nitrate + nitrite (as N) is 10.0 mg/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 10/14/2008-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 119842, Nitrate/Nitrite (Nitrite + Nitrate as N)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 192027
 
Pollutant: Nitrate/Nitrite (Nitrite + Nitrate as N)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 70
Number of Exceedances: 2
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 2 of 70 samples exceeded the water quality threshold for Nitrate + Nitrite as N.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nitrate + nitrite (as N) incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 10 mg/L (California Code of Regulations, Title 22).
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2016-09-20
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119843
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Oxamyl (Vydate)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 119843, Oxamyl (Vydate)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 192557
 
Pollutant: Oxamyl (Vydate)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 38
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 38 samples exceeded the water quality threshold for Oxamyl.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for Oxamyl incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.05 mg/L
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2016-09-20
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119844
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Selenium
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119844, Selenium
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 193311
 
Pollutant: Selenium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Selenium.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for selenium incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.05 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
Line of Evidence (LOE) for Decision ID 119844, Selenium
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71125
 
Pollutant: Selenium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 11
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 2 samples exceed the criterion for Selenium.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for selenium is 0.05 mg/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
119845
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Simazine
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119845, Simazine
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71128
 
Pollutant: Simazine
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Simazine.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for Simazine is 4 ug/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 119845, Simazine
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 193560
 
Pollutant: Simazine
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 37
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 37 samples exceeded the water quality threshold for Simazine.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Primary Maximum Contaminant Level for Simazine incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 0.004 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2016-09-20
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
126602
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Specific Conductivity
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 126602, Specific Conductivity
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71382
 
Pollutant: Specific Conductivity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 35
Number of Exceedances: 12
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 12 of 35 samples exceed the criterion for Conductivity(Us).
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California secondary maximum contaminant levels for electrical conductivity provide a range of values including a recommended level (900 uS/cm), an upper level (1,600 uS/cm) and a short-term level (2,200 uS/cm). The recommended level of 900 uS/cm was used as it is protective of all drinking water uses.
Objective/Criterion Reference: Secondary Maximum Contaminant Levels and Compliance. CCR Title 22 section 64449.
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 126602, Specific Conductivity
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 229983
 
Pollutant: Specific Conductivity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 74
Number of Exceedances: 21
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 21 of 74 samples exceeded the water quality threshold for SpecificConductivity.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary MCL that is incorporated by reference in the Water Quality Control Plan, Central Valley Region Sacramento River Basin and San Joaquin River Basin for specific conductance is 900 uS/cm.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2016-12-16
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119846
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Total Dissolved Solids
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 119846, Total Dissolved Solids
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 194069
 
Pollutant: Total Dissolved Solids
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 49
Number of Exceedances: 21
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 21 of 49 samples exceeded the water quality threshold for Total Dissolved Solids.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary Maximum Contaminant Level for total dissolved solids incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 500 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2014-09-16
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
119847
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Zinc
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Readily available data for this water body have not been used to determine standards attainment. No decision has been made regarding beneficial use support due to a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule. A decision regarding the beneficial use support of this water body will be made during a future Integrated Report cycle if it is determined that this water body is classified as a Water of the United States under the Navigable Waters Protection Rule.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the listing status for this water body-pollutant combination should not change this cycle because of a lack of clarity in the status of this water body under the Clean Water Act and the Navigable Waters Protection Rule.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 119847, Zinc
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 194404
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Zinc.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary Maximum Contaminant Level for zinc incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 5.0 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
Line of Evidence (LOE) for Decision ID 119847, Zinc
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71155
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Zinc.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California secondary maximum contaminant level for zinc is 5.0 mg/L.
Objective/Criterion Reference: Secondary Maximum Contaminant Levels and Compliance. CCR Title 22 section 64449.
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
Line of Evidence (LOE) for Decision ID 119847, Zinc
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 194312
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 16
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed San Joaquin County Delta Water Quality Coalition data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 16 samples exceeded the water quality threshold for Zinc.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary Maximum Contaminant Level for zinc incorporated by reference in the Water Quality Control Plan for the Sacramento and San Joaquin River Basins is 5.0 mg/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (544XTTHWT)
Temporal Representation: The samples were collected between the dates of 2010-09-07 and 2013-12-17
Environmental Conditions:
QAPP Information: Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2010. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0) ., Prepared by Michael L. Johnson LLC for the Irrigated Lands Program. 2015. Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0) ., Michael L. Johnson LLC. 2015. Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition .
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 2.0)
QAPP Information Reference(s): Quality Assurance Project Plan For Monitoring By The San Joaquin County & Delta Water Quality Coalition (Revision 3.0)
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring By the San Joaquin County & Delta Water Quality Coalition
 
 
DECISION ID
89587
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Aldrin
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 89587, Aldrin
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71225
 
Pollutant: Aldrin
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 0 samples exceed the criterion for Aldrin.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The CTR objective for aldrin to protect human health from the consumption of water and organisms is 0.00013 ug/L.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 5/12/2009-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88354
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Heptachlor
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88354, Heptachlor
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71405
 
Pollutant: Heptachlor
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 0 samples exceed the criterion for Heptachlor.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The CTR objective for Heptachlor to protect human health from the consumption of water and organisms is 0.00021 ug/L.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 5/12/2009-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88355
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Heptachlor epoxide
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88355, Heptachlor epoxide
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71407
 
Pollutant: Heptachlor epoxide
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 0 samples exceed the criterion for Heptachlor epoxide.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The CTR objective for Heptachlor epoxide to protect human health from the consumption of water and organisms is 0.0001 ug/L.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 5/12/2009-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88356
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Lindane/gamma Hexachlorocyclohexane (gamma-HCH)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88356, Lindane/gamma Hexachlorocyclohexane (gamma-HCH)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71409
 
Pollutant: Lindane/gamma Hexachlorocyclohexane (gamma-HCH)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 8
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 8 samples exceed the criterion for HCH, gamma.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for HCH, gamma (Lindane) is 0.2 ug/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 5/12/2009-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88358
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Molinate
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88358, Molinate
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71475
 
Pollutant: Molinate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Molinate.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for Molinate is 20 ug/L .
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88360
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Nitrogen, Nitrate
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88360, Nitrogen, Nitrate
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71478
 
Pollutant: Nitrogen, Nitrate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Nitrate as N.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for nitrate (NO3 as N) is 10.0 mg/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88361
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Nitrogen, Nitrite
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88361, Nitrogen, Nitrite
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71479
 
Pollutant: Nitrogen, Nitrite
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Nitrite as N.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California primary maximum contaminant level for nitrite (as N) is 1 mg/L.
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88437
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Thiobencarb/Bolero
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88437, Thiobencarb/Bolero
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71152
 
Pollutant: Thiobencarb/Bolero
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 15 samples exceed the criterion for Thiobencarb.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of Thiobencarb in excess of 1.0 µg/L. (Water Quality Control Plan, Central Valley Region, Sacramento River Basin and San Joaquin River Basin)
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 2/11/2007-9/16/2008.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88438
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: Toxaphene
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88438, Toxaphene
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71153
 
Pollutant: Toxaphene
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 0 samples exceed the criterion for Toxaphene.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Toxaphene criterion for the protection of human health from the consumption of water and organisms is 0.00073 ug/L. (California Toxics Rule, 2000)
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 5/12/2009-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88440
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: alpha-Endosulfan (Endosulfan 1)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88440, alpha-Endosulfan (Endosulfan 1)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71228
 
Pollutant: alpha-Endosulfan (Endosulfan 1)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 8
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 8 samples exceed the criterion for Endosulfan I.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Endosulfan I criterion for the protection of human health from consumption of water and organisms is 110 ug/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 5/12/2009-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88441
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: alpha.-BHC (Benzenehexachloride or alpha-HCH)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88441, alpha.-BHC (Benzenehexachloride or alpha-HCH)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71227
 
Pollutant: alpha.-BHC (Benzenehexachloride or alpha-HCH)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 0 samples exceed the criterion for HCH, alpha.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The HCH, alpha criterion, 0.0039 ug/L, is for the protection of human health from the consumption of water and organisms. (California Toxics Rule, 2002)
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 5/12/2009-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88442
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: beta-BHC (Benzenehexachloride or beta-HCH)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88442, beta-BHC (Benzenehexachloride or beta-HCH)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71281
 
Pollutant: beta-BHC (Benzenehexachloride or beta-HCH)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 8
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 8 samples exceed the criterion for HCH, beta.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The HCH, beta criterion for the protection of human health from the consumption of water and organisms is 0.014 ug/L (California Toxics Rule, 2002).
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 5/12/2009-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.
 
 
DECISION ID
88443
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
Pollutant: beta-Endosulfan (Endosulfan 2)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Data for this water segment-pollutant combination were received by the State Water Resources Control Board as part of the data solicitation for the 2014 Integrated Report Cycle. These data were not assessed as part of the 2014 Integrated Report.
 
Regional Board Decision Recommendation: Data for this water segment - pollutant combination were not assessed by RWQCB staff during the 2014 Integrated Report cycle. RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list at this time. These data will be assessed by RWQCB staff during a future Integrated Report cycle to determine the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88443, beta-Endosulfan (Endosulfan 2)
Region 5     
Terminous Tract Drain, at Hwy 12 (San Joaquin County)
 
LOE ID: 71282
 
Pollutant: beta-Endosulfan (Endosulfan 2)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 8
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed Ag Waiver data for Terminous Tract Drain, at Hwy 12 (San Joaquin County) to determine beneficial use support and results are as follows: 0 of 8 samples exceed the criterion for Endosulfan II.
Data Reference: Data for Various Pollutants in San Joaquin and Delta Water Quality Coalition, 2004-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The beta-endosulfan criterion for the protection of human health from consumption of water and organisms is 110 ug/L. (California Toxics Rule, 2000)
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Terminous Tract Drain, at Hwy 12 (San Joaquin County) was collected at 1 monitoring site [Terminous Tract Drain @ Hwy 12 - 544XTTHWT]
Temporal Representation: Data was collected over the time period 5/12/2009-12/8/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: Data for this line of evidence was collected as part of the Irrigated Lands Regulatory Program.
QAPP Information Reference(s): Quality Assurance Project Plan for Monitoring by the San Joaquin County and Delta Water Quality Coalition.