Draft California 2020 Integrated Report (303(d) List/305(b) Report)

Supporting Information

Regional Board 7 - Colorado River Basin Region

Water Body Name: West Branch Millard Canyon Creek
Water Body ID: CAR7193200020171213033695
Water Body Type: River & Stream
 
DECISION ID
101325
Region 7     
West Branch Millard Canyon Creek
 
Pollutant: Chloride
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2, a single line of evidence is necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of the four sample(s) exceed the water quality standard for each of the two beneficial uses.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of the four sample(s) exceed the water quality standard for each of the two beneficial uses and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 101325, Chloride
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126827
 
Pollutant: Chloride
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 4
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 0 of 4 samples exceeded the water quality standard for Chloride.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Chloride criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater is 230000 ug/L (230 mg/L)(USEPA National Recommended Water Quality Criteria, 2006).
Objective/Criterion Reference: National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Office of Science and Technology
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 2 monitoring site(s) (MORONGO1_WQX-M003, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2011-04-20 and 2012-04-25
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
Line of Evidence (LOE) for Decision ID 101325, Chloride
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126708
 
Pollutant: Chloride
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 4
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 0 of 4 samples exceeded the water quality standard for Chloride.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual chemical or combination of chemicals shall be present in concentrations that adversely affect beneficial uses.
Objective/Criterion Reference: Water Quality Control Plan for the Colorado River Basin Region (Includes amendments effective on or before January 8, 2019)
 
Evaluation Guideline: The Drinking Water Secondary Maximum Contaminant Levels (SMCLs) for consumer acceptance were used: 500 mg/l Chloride (CCR, title 22).
Guideline Reference: California Code of Regulations, Title 22, Division 4, Chapter 15. Domestic Water Quality and Monitoring
 
Spatial Representation: The samples were collected at 2 monitoring site(s) (MORONGO1_WQX-M003, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2011-04-20 and 2012-04-25
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
 
DECISION ID
101330
Region 7     
West Branch Millard Canyon Creek
 
Pollutant: Iron
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1, a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of the three sample(s) exceed the water quality standard.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of the three sample(s) exceed the water quality standard and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 101330, Iron
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126816
 
Pollutant: Iron
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 3
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 0 of 3 samples exceeded the water quality standard for Iron.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual chemical or combination of chemicals shall be present in concentrations that adversely affect beneficial uses. (Water Quality Control Plan, Colorado River Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Colorado River Basin Region (Includes amendments effective on or before January 8, 2019)
 
Evaluation Guideline: The California Secondary MCL for iron is 0.3 mg/L (Title 22 California Code of Regulations).
Guideline Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Spatial Representation: The samples were collected at 2 monitoring site(s) (MORONGO1_WQX-M003, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2011-04-20 and 2012-04-25
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
 
DECISION ID
101331
Region 7     
West Branch Millard Canyon Creek
 
Pollutant: Nitrogen, Nitrate
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1, a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of the four sample(s) exceed the water quality standard.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of the four samples exceed the water quality standard and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 101331, Nitrogen, Nitrate
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126829
 
Pollutant: Nitrogen, Nitrate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 4
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 0 of 4 samples exceeded the water quality standard for Nitrate as N.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for Nitrate as N is 10000 ug/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 2 monitoring site(s) (MORONGO1_WQX-M003, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2011-04-20 and 2012-04-25
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
 
DECISION ID
101326
Region 7     
West Branch Millard Canyon Creek
 
Pollutant: Oxygen, Dissolved
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2, a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. One of the 15 sample(s) exceed the water quality standard for the beneficial use assessed.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. One of 15 sample(s) exceed the water quality standard for the beneficial use assessed and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 101326, Oxygen, Dissolved
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126733
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 15
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 1 of 15 samples exceeded the water quality standard for Oxygen, Dissolved.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water Quality Control Plan, Colorado River Basin, WARM Water Habitat Objective, Chapter III, states the following: The dissolved oxygen concentration for cold water habitats shall not be reduced below 5.0 mg/l at any time.
Objective/Criterion Reference: Water Quality Control Plan for the Colorado River Basin Region (Includes amendments effective on or before January 8, 2019)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 4 monitoring site(s) (MORONGO1_WQX-M001, MORONGO1_WQX-M003, MORONGO1_WQX-Millard 002, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2010-10-14 and 2012-07-10
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
 
DECISION ID
101327
Region 7     
West Branch Millard Canyon Creek
 
Pollutant: Total Dissolved Solids
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2, a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. One of the 14 sample(s) exceed the water quality standard for the beneficial use assessed.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. One of 14 sample(s) exceed the water quality standard for the beneficial use assessed and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 101327, Total Dissolved Solids
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126690
 
Pollutant: Total Dissolved Solids
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 14
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 0 of 14 samples exceeded the water quality standard for Total Dissolved Solids.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual chemical or combination of chemicals shall be present in concentrations that adversely affect beneficial uses.
Objective/Criterion Reference: Water Quality Control Plan for the Colorado River Basin Region (Includes amendments effective on or before January 8, 2019)
 
Evaluation Guideline: California Secondary Maximum Contaminant Levels (MCLs) for consumer acceptance objective for total dissolved solids is 500 mg/L.
Guideline Reference: California Code of Regulations, Title 22, Division 4, Chapter 15. Domestic Water Quality and Monitoring
 
Spatial Representation: The samples were collected at 4 monitoring site(s) (MORONGO1_WQX-M001, MORONGO1_WQX-M003, MORONGO1_WQX-Millard 002, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2010-10-14 and 2012-07-10
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
 
DECISION ID
101329
Region 7     
West Branch Millard Canyon Creek
 
Pollutant: pH
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2, a single line of evidence is necessary to assess listing status.

Five lines of evidence are available in the administrative record to assess this pollutant. Zero of the 15 sample(s) exceed the water quality standard for each of the five beneficial uses assessed.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of the 15 samples exceed the water quality standard for each of the five beneficial uses assessed and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 101329, pH
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126722
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Freshwater Replenishment
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 0 of 15 samples exceeded the water quality standard for pH.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan for the Colorado River Basin Region's water quality objective for all surface waters states the following: Since the regional waters are somewhat alkaline, pH shall range from 6.0-9.0. Discharges shall not cause any changes in pH detrimental to beneficial water uses.
Objective/Criterion Reference: Water Quality Control Plan for the Colorado River Basin Region (Includes amendments effective on or before January 8, 2019)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 4 monitoring site(s) (MORONGO1_WQX-M001, MORONGO1_WQX-M003, MORONGO1_WQX-Millard 002, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2010-10-14 and 2012-07-10
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
Line of Evidence (LOE) for Decision ID 101329, pH
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126808
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 0 of 15 samples exceeded the water quality standard for pH.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan for the Colorado River Basin Region's water quality objective for all surface waters states the following: Since the regional waters are somewhat alkaline, pH shall range from 6.0-9.0. Discharges shall not cause any changes in pH detrimental to beneficial water uses.
Objective/Criterion Reference: Water Quality Control Plan for the Colorado River Basin Region (Includes amendments effective on or before January 8, 2019)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 4 monitoring site(s) (MORONGO1_WQX-M001, MORONGO1_WQX-M003, MORONGO1_WQX-Millard 002, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2010-10-14 and 2012-07-10
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
Line of Evidence (LOE) for Decision ID 101329, pH
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126797
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Non-Contact Recreation
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 0 of 15 samples exceeded the water quality standard for pH.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan for the Colorado River Basin Region's water quality objective for all surface waters states the following: Since the regional waters are somewhat alkaline, pH shall range from 6.0-9.0. Discharges shall not cause any changes in pH detrimental to beneficial water uses.
Objective/Criterion Reference: Water Quality Control Plan for the Colorado River Basin Region (Includes amendments effective on or before January 8, 2019)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 4 monitoring site(s) (MORONGO1_WQX-M001, MORONGO1_WQX-M003, MORONGO1_WQX-Millard 002, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2010-10-14 and 2012-07-10
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
Line of Evidence (LOE) for Decision ID 101329, pH
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126742
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 0 of 15 samples exceeded the water quality standard for pH.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan for the Colorado River Basin Region's water quality objective for all surface waters states the following: Since the regional waters are somewhat alkaline, pH shall range from 6.0-9.0. Discharges shall not cause any changes in pH detrimental to beneficial water uses.
Objective/Criterion Reference: Water Quality Control Plan for the Colorado River Basin Region (Includes amendments effective on or before January 8, 2019)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 4 monitoring site(s) (MORONGO1_WQX-M001, MORONGO1_WQX-M003, MORONGO1_WQX-Millard 002, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2010-10-14 and 2012-07-10
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
Line of Evidence (LOE) for Decision ID 101329, pH
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126798
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 15
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 0 of 15 samples exceeded the water quality standard for pH.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan for the Colorado River Basin Region's water quality objective for all surface waters states the following: Since the regional waters are somewhat alkaline, pH shall range from 6.0-9.0. Discharges shall not cause any changes in pH detrimental to beneficial water uses.
Objective/Criterion Reference: Water Quality Control Plan for the Colorado River Basin Region (Includes amendments effective on or before January 8, 2019)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 4 monitoring site(s) (MORONGO1_WQX-M001, MORONGO1_WQX-M003, MORONGO1_WQX-Millard 002, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2010-10-14 and 2012-07-10
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.
 
 
DECISION ID
101328
Region 7     
West Branch Millard Canyon Creek
 
Pollutant: Turbidity
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Sources: A Source Unknown
Expected TMDL Completion Date: 2031
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence are available in the administrative record to assess this pollutant. Nine of the fifteen samples exceed the guideline.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Nine of the fifteen samples exceed the guideline and this exceeds the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 101328, Turbidity
Region 7     
West Branch Millard Canyon Creek
 
LOE ID: 126775
 
Pollutant: Turbidity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 15
Number of Exceedances: 9
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed STORET data for West Branch Millard Canyon Creek to determine beneficial use support and results are as follows: 9 of 15 samples exceeded the water quality standard for Turbidity.
Data Reference: Water quality data for federal, state, and tribal agencies submitted through the US EPA STorage and RETrival (STORET) database for the 2018 listing cycle.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Aesthetic Qualities. All waters shall be free from substances attributable to wastewater of domestic or industrial origin or other discharges which adversely affect beneficial uses not limited to: Producing objectionable color, odor, taste, or turbidity. (Water Quality Control Plan, Colorado River Basin Region).
Objective/Criterion Reference: Water Quality Control Plan for the Colorado River Basin Region (Includes amendments effective on or before January 8, 2019)
 
Evaluation Guideline: The California Maximum Contaminant Levels (MCLs) apply to ambient surface waters under the Basin Plan's narrative objective for Aesthetic Qualities. The Secondary MCL for turbidity is 5 nephelometric turbidity units (NTU). (Cal. Code Regs., tit. 22, ยง 64449.)
Guideline Reference: California Code of Regulations, Title 22, Division 4, Chapter 15. Domestic Water Quality and Monitoring
 
Spatial Representation: The samples were collected at 4 monitoring site(s) (MORONGO1_WQX-M001, MORONGO1_WQX-M003, MORONGO1_WQX-Millard 002, MORONGO1_WQX-SPS)
Temporal Representation: The samples were collected between the dates of 2010-10-14 and 2012-07-10
Environmental Conditions:
QAPP Information: QAPP not required for federal data
QAPP Information Reference(s): This is a placeholder reference for data that was collected after QAPP requirements were developed, but exempt from the requirements.