Water Body Name: | Stevens Creek, tributary to Big Meadow Creek |
Water Body ID: | CAR6341001020171102051051 |
Water Body Type: | River & Stream |
DECISION ID |
102038 |
Region 6 |
Stevens Creek, tributary to Big Meadow Creek |
||
Pollutant: | Alkalinity as CaCO3 |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.
One line of evidence are available in the administrative record to assess this pollutant. 1 of 2 samples exceed the water quality objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 1 of 2 samples exceeded the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples are needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 98457 | ||||
Pollutant: | Alkalinity as CaCO3 | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 2 | ||||
Number of Exceedances: | 1 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed TRPA Tahoe Ambient Monitoring data for Stevens Creek, tributary to Big Meadow Creek to determine beneficial use support and results are as follows: 1 of 2 samples exceeded the water quality standard for Alkalinity as CaCO3. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for the Tahoe Regional Planning Agency (TRPA) Tahoe Ambient Monitoring program. | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | The National Recommended Water Quality Criteria for Alkalinity as CaCO3 for the protection of freshwater aquatic life is not less than 20000 ug/L. (National Recommended Water Quality Criteria 2016) | ||||
Objective/Criterion Reference: | National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Current as of 08/03/2016. | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 2 monitoring site(s) (634S16297, 634S16309) | ||||
Temporal Representation: | The samples were collected between the dates of 2016-07-20 and 2016-09-21 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
102039 |
Region 6 |
Stevens Creek, tributary to Big Meadow Creek |
||
Pollutant: | Oxygen, Dissolved |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.
Two lines of evidence, one which evaluates the available dissolved oxygen data and one which evaluates the available dissolved oxygen saturation data, are available in the administrative record to assess this pollutant. 1 of 2 dissolved oxygen saturation samples exceed the water quality objective; 0 of 2 dissolved oxygen samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used do not satisfy the data quantity requirements of section 6.1.5 of the Policy. 3. 1 of 2 dissolved oxygen saturation samples exceed the water quality objective; 0 of 2 dissolved oxygen samples exceed the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples per fraction assessed are needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 130148 | ||||
Pollutant: | Oxygen, Dissolved | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 2 | ||||
Number of Exceedances: | 1 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed TRPA Tahoe Ambient Monitoring data for Stevens Creek, tributary to Big Meadow Creek to determine beneficial use support and results are as follows: 1 of 2 samples exceeded the water quality standard for Oxygen, Saturation. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for the Tahoe Regional Planning Agency (TRPA) Tahoe Ambient Monitoring program. | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | The Water Quality Control Plan for the Lahontan Region's water quality objective states that the dissolved oxygen concentration shall not be less than 80 percent of saturation. | ||||
Objective/Criterion Reference: | Water Quality Control Plan for the Lahontan Region (as amended) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 2 monitoring site(s) (634S16297, 634S16309) | ||||
Temporal Representation: | The samples were collected between the dates of 2016-07-20 and 2016-09-21 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 130136 | ||||
Pollutant: | Oxygen, Dissolved | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 2 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed TRPA Tahoe Ambient Monitoring data for Stevens Creek, tributary to Big Meadow Creek to determine beneficial use support and results are as follows: 0 of 2 samples exceeded the water quality standard for Oxygen, Dissolved. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for the Tahoe Regional Planning Agency (TRPA) Tahoe Ambient Monitoring program. | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | For waters with the beneficial uses of COLD, COLD with SPWN, WARM, and WARM with SPWN, the minimum dissolved oxygen concentration shall not be less than that specified in Table 3-6. (Water Quality Control Plan, Lahontan Region) | ||||
Objective/Criterion Reference: | Water Quality Control Plan for the Lahontan Region (as amended) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 2 monitoring site(s) (634S16297, 634S16309) | ||||
Temporal Representation: | The samples were collected between the dates of 2016-07-20 and 2016-09-21 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
102048 |
Region 6 |
Stevens Creek, tributary to Big Meadow Creek |
||
Pollutant: | Specific Conductivity |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.
One line of evidence are available in the administrative record to assess this pollutant. 0 of 2 samples exceed the water quality objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 2 samples exceeded the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples are needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 97353 | ||||
Pollutant: | Specific Conductivity | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 2 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed TRPA Tahoe Ambient Monitoring data for Stevens Creek, tributary to Big Meadow Creek to determine beneficial use support and results are as follows: 0 of 2 samples exceeded the water quality standard for SpecificConductivity. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for the Tahoe Regional Planning Agency (TRPA) Tahoe Ambient Monitoring program. | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water designated as MUN shall not contain concentrations of chemical constituents in excess of the maximum contaminant level (MCL) or secondary maximum contaminant level (SMCL) based upon drinking water standards specified in Title 22 of the California Code of Regulations (Water Quality Control Plan, Lahontan Region). | ||||
Objective/Criterion Reference: | Water Quality Control Plan for the Lahontan Region (as amended) | ||||
Evaluation Guideline: | California Maximum Contaminant Levels (MCLs) apply to ambient waters under the Lahontan Basin Plan's \Chemical Constituents\" objective. The California Secondary MCL for specific conductivity is 900 uS/cm." | ||||
Guideline Reference: | California Code of Regulations, Title 22, Division 4, Chapter 15. Domestic Water Quality and Monitoring | ||||
Spatial Representation: | The samples were collected at 2 monitoring site(s) (634S16297, 634S16309) | ||||
Temporal Representation: | The samples were collected between the dates of 2016-07-20 and 2016-09-21 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
102049 |
Region 6 |
Stevens Creek, tributary to Big Meadow Creek |
||
Pollutant: | pH |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. pH assessments require baseline information regarding water quality conditions in the water body which is unavailable at this time, the result of which computes zero samples available for assessment. Therefore, 0 of 0 samples exceed the water quality objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. 0 of 0 samples exceeded the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples are needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 129825 | ||||
Pollutant: | pH | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | 0 of 0 samples exceeded the water quality standard for pH. Although pH data does exist for this waterbody, the objective for this pollutant requires background information that is currently unavailable, and therefore an assessment of water quality standards could not be made. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for the Tahoe Regional Planning Agency (TRPA) Tahoe Ambient Monitoring program. | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | The Lahontan Basin Plan's regionwide objective for pH states: \In fresh waters with designated beneficial uses of COLD or WARM, changes in normal ambient pH levels shall not exceed 0.5 pH units. For all other waters of the region, the pH shall not be depressed below 6.5 nor raised above 8.5 units. The Regional Board recognizes that some waters of the Region may have natural pH levels outside of the 6.5 to 8.5 range. Compliance with the pH objective for these waters will be determined on a case-by-case basis.\"" | ||||
Objective/Criterion Reference: | Water Quality Control Plan for the Lahontan Region (as amended) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 2 monitoring site(s) (634S16297, 634S16309) | ||||
Temporal Representation: | The samples were collected between the dates of 2016-07-20 and 2016-09-21 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 129826 | ||||
Pollutant: | pH | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | 0 of 0 samples exceeded the water quality standard for pH. Although pH data does exist for this waterbody, the objective for this pollutant requires background information that is currently unavailable, and therefore an assessment of water quality standards could not be made. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for the Tahoe Regional Planning Agency (TRPA) Tahoe Ambient Monitoring program. | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | The Lahontan Basin Plan's regionwide objective for pH states: \In fresh waters with designated beneficial uses of COLD or WARM, changes in normal ambient pH levels shall not exceed 0.5 pH units. For all other waters of the region, the pH shall not be depressed below 6.5 nor raised above 8.5 units. The Regional Board recognizes that some waters of the Region may have natural pH levels outside of the 6.5 to 8.5 range. Compliance with the pH objective for these waters will be determined on a case-by-case basis.\"" | ||||
Objective/Criterion Reference: | Water Quality Control Plan for the Lahontan Region (as amended) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 2 monitoring site(s) (634S16297, 634S16309) | ||||
Temporal Representation: | The samples were collected between the dates of 2016-07-20 and 2016-09-21 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||