Draft California 2020 Integrated Report (303(d) List/305(b) Report)

Supporting Information

Regional Board 3 - Central Coast Region

Water Body Name: Zaca Lake
Water Body ID: CAL3143001020191031041649
Water Body Type: Lake & Reservoir
 
DECISION ID
129370
Region 3     
Zaca Lake
 
Pollutant: Ammonia
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.

Ten lines of evidence (LOEs) are available in the administrative record to assess this pollutant.
The following is a summary of the sample and exceedances for each beneficial use:

Based on LOEs summarizing un-ionized ammonia data, zero of the zero samples exceed the water quality objective (Basin Plan) set to protect aquatic life. Although a total of two samples were collected, two of these samples were not included in the assessment because the laboratory data reporting limit(s) was above the water quality threshold and therefore the results could not be quantified with the level of certainty required by the Listing Policy.

Based on LOEs summarizing total ammonia data (‘nitrogen, ammonia’ and ‘nitrogen as ammonia’) zero of the two samples exceed the EPA's Aquatic Life Ambient Water Quality Criteria set to protect aquatic life.

Based on LOEs summarizing total ammonia data (‘nitrogen, ammonia’ and ‘nitrogen as ammonia’) zero of the two samples exceed the EPA's Lifetime Health advisory level set to protect municipal and domestic supply uses.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List in the Water Quality Limited Segments category. This sample size is insufficient to determine an applicable beneficial use support rating with the power and confidence of the Listing Policy. In accordance with Table 3.1 of the Listing Policy, a minimum of 16 samples is needed to determine if a beneficial use is fully supported and a minimum of two exceedances is needed to determine if beneficial uses are not supported.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of the samples exceed the water quality objectives and this does not exceed the allowable frequency listed in Table 3.1 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) List. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 129370, Ammonia
Region 3     
Zaca Lake
 
LOE ID: 184097
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Ammonia as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Total Ammonia criterion continuous concentration (expressed as a 30-day average) to protect aquatic life in freshwater is Temperature and pH dependent, and was calculated according to the formula listed in the Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013 document.
Objective/Criterion Reference: Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 129370, Ammonia
Region 3     
Zaca Lake
 
LOE ID: 219643
 
Pollutant: Ammonia (Unionized)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support, and the results are as follows: 0 of the 0 samples exceeded the evaluation guideline for Ammonia as N, Unionized. Although a total of 1 samples were collected, 1 of these samples were not included in the assessment because the laboratory data reporting limit(s) was above the water quality threshold and therefore the results could not be quantified with the level of certainty required by the Listing Policy Section 6.1.5.5.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Water Quality Control Plan, Central Coast Basin General Objective, Chapter 3, Section 3.3.2 (Objectives for all Inland Surface Waters, Enclosed Bays, and Estuaries) states that the discharge of wastes shall not cause concentrations of unionized ammonia (NH3) to exceed 0.025 mg/L (as N) in receiving waters (page 32).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2).
Temporal Representation: Date for this waterbody was collected over the date range 2017-05-18 to 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 129370, Ammonia
Region 3     
Zaca Lake
 
LOE ID: 184099
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Ammonia as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: All waters shall be maintained free of toxic substances in concentrations which are toxic to, or which produce detrimental physiological responses in, human, plant, animal, or aquatic life. (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: EPA's Lifetime Health advisory level for total ammonia is 30.0 mg/L as stated on page 8 of the 2012 edition of the drinking water standards and health advisories. This Advisory Level is defined as 'the concentration of a chemical in drinking water that is not expected to cause any adverse noncarcinogenic effects for a lifetime of exposure.'
Guideline Reference: 2018 Edition of the Drinking Water Standards and Health Advisories
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 129370, Ammonia
Region 3     
Zaca Lake
 
LOE ID: 183693
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Ammonia as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Total Ammonia criterion continuous concentration (expressed as a 30-day average) to protect aquatic life in freshwater is Temperature and pH dependent, and was calculated according to the formula listed in the Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013 document.
Objective/Criterion Reference: Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 129370, Ammonia
Region 3     
Zaca Lake
 
LOE ID: 184169
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Ammonia as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Total Ammonia criterion continuous concentration (expressed as a 30-day average) to protect aquatic life in freshwater is Temperature and pH dependent, and was calculated according to the formula listed in the Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013 document.
Objective/Criterion Reference: Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 129370, Ammonia
Region 3     
Zaca Lake
 
LOE ID: 184297
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Ammonia as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Total Ammonia criterion continuous concentration (expressed as a 30-day average) to protect aquatic life in freshwater is Temperature and pH dependent, and was calculated according to the formula listed in the Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013 document.
Objective/Criterion Reference: Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 129370, Ammonia
Region 3     
Zaca Lake
 
LOE ID: 184098
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Ammonia as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: All waters shall be maintained free of toxic substances in concentrations which are toxic to, or which produce detrimental physiological responses in, human, plant, animal, or aquatic life. (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: EPA's Lifetime Health advisory level for total ammonia is 30.0 mg/L as stated on page 8 of the 2012 edition of the drinking water standards and health advisories. This Advisory Level is defined as 'the concentration of a chemical in drinking water that is not expected to cause any adverse noncarcinogenic effects for a lifetime of exposure.'
Guideline Reference: 2018 Edition of the Drinking Water Standards and Health Advisories
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 129370, Ammonia
Region 3     
Zaca Lake
 
LOE ID: 219420
 
Pollutant: Ammonia (Unionized)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support, and the results are as follows: 0 of the 0 samples exceeded the evaluation guideline for Ammonia as N, Unionized. Although a total of 1 samples were collected, 1 of these samples were not included in the assessment because the laboratory data reporting limit(s) was above the water quality threshold and therefore the results could not be quantified with the level of certainty required by the Listing Policy Section 6.1.5.5.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Water Quality Control Plan, Central Coast Basin General Objective, Chapter 3, Section 3.3.2 (Objectives for all Inland Surface Waters, Enclosed Bays, and Estuaries) states that the discharge of wastes shall not cause concentrations of unionized ammonia (NH3) to exceed 0.025 mg/L (as N) in receiving waters (page 32).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1).
Temporal Representation: Date for this waterbody was collected over the date range 2017-05-18 to 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 129370, Ammonia
Region 3     
Zaca Lake
 
LOE ID: 219524
 
Pollutant: Ammonia (Unionized)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support, and the results are as follows: 0 of the 0 samples exceeded the evaluation guideline for Ammonia as N, Unionized. Although a total of 1 samples were collected, 1 of these samples were not included in the assessment because the laboratory data reporting limit(s) was above the water quality threshold and therefore the results could not be quantified with the level of certainty required by the Listing Policy Section 6.1.5.5.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Water Quality Control Plan, Central Coast Basin General Objective, Chapter 3, Section 3.3.2 (Objectives for all Inland Surface Waters, Enclosed Bays, and Estuaries) states that the discharge of wastes shall not cause concentrations of unionized ammonia (NH3) to exceed 0.025 mg/L (as N) in receiving waters (page 32).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2).
Temporal Representation: Date for this waterbody was collected over the date range 2017-05-18 to 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 129370, Ammonia
Region 3     
Zaca Lake
 
LOE ID: 219475
 
Pollutant: Ammonia (Unionized)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support, and the results are as follows: 0 of the 0 samples exceeded the evaluation guideline for Ammonia as N, Unionized. Although a total of 1 samples were collected, 1 of these samples were not included in the assessment because the laboratory data reporting limit(s) was above the water quality threshold and therefore the results could not be quantified with the level of certainty required by the Listing Policy Section 6.1.5.5.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Water Quality Control Plan, Central Coast Basin General Objective, Chapter 3, Section 3.3.2 (Objectives for all Inland Surface Waters, Enclosed Bays, and Estuaries) states that the discharge of wastes shall not cause concentrations of unionized ammonia (NH3) to exceed 0.025 mg/L (as N) in receiving waters (page 32).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1).
Temporal Representation: Date for this waterbody was collected over the date range 2017-05-18 to 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
 
DECISION ID
126063
Region 3     
Zaca Lake
 
Pollutant: Escherichia coli (E. coli)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the Clean Water Act section 303(d) List under sections 3.2 and 3.3 of the Listing Policy. Under these sections, a single line of evidence is necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero out of the two samples exceed water quality objective (ISWEBE, SWRCB 2019) for water contact recreation. This sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is supported and a minimum of five exceedances is needed to determine if beneficial uses are not supported using Table 3.2 of the Listing Policy. Therefore, the use support rating is set to 'insufficient information'.

After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) List because applicable water quality standards are not being exceeded.

This conclusion is based on the staff findings that:

1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero out of the two samples exceed water quality objective (ISWEBE, SWRCB 2019) for water contact recreation. and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) List. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 126063, Escherichia coli (E. coli)
Region 3     
Zaca Lake
 
LOE ID: 150395
 
Pollutant: Escherichia coli (E. coli)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed data for Zaca Lake to determine beneficial use support and the results are as follows: 0 of the 1 samples exceeded the Statistical Threshold Value (STV) water quality threshold for E. coli. The STV is based on a 10% exceedance rate that is calculated monthly.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The bacteria water quality objective applicable to all non-saline waters, is a Statistical Threshold Value (STV) of 320 cfu/100 mL. The applicable STV shall not be exceeded by more than 10 percent of the samples collected in a calendar month, calculated in a static manner (ISWEBE 2018).
Objective/Criterion Reference: Inland Surface Waters, Enclosed Bays, and Estuaries Plan. Part 1: Trash Provisions; Part 2: Tribal Subsistence Beneficial Uses and Mercury Provisions; Part 3: Bacteria Provisions and Variance Policy
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site(s), station(s): 314ZCALK2
Temporal Representation: The samples were collected between the days of 2017-05-18 and 2017-05-18 .
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 126063, Escherichia coli (E. coli)
Region 3     
Zaca Lake
 
LOE ID: 150394
 
Pollutant: Escherichia coli (E. coli)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed data for Zaca Lake to determine beneficial use support and the results are as follows: 0 of the 1 samples exceeded the Statistical Threshold Value (STV) water quality threshold for E. coli. The STV is based on a 10% exceedance rate that is calculated monthly.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The bacteria water quality objective applicable to all non-saline waters, is a Statistical Threshold Value (STV) of 320 cfu/100 mL. The applicable STV shall not be exceeded by more than 10 percent of the samples collected in a calendar month, calculated in a static manner (ISWEBE 2018).
Objective/Criterion Reference: Inland Surface Waters, Enclosed Bays, and Estuaries Plan. Part 1: Trash Provisions; Part 2: Tribal Subsistence Beneficial Uses and Mercury Provisions; Part 3: Bacteria Provisions and Variance Policy
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site(s), station(s): 314ZCALK1
Temporal Representation: The samples were collected between the days of 2017-05-18 and 2017-05-18 .
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
 
DECISION ID
130276
Region 3     
Zaca Lake
 
Pollutant: Fecal Coliform
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.3 of the Listing Policy. Under section 3.3 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant.

Zero of the one sample exceeded the water quality objective for non-contact recreation. This sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is supported and a minimum of five exceedances is needed to determine if beneficial uses are not supported using table 3.2. Therefore, the use support rating is set to 'insufficient information'.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of the one sample exceeds the water quality objective for non-contact recreation and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the CWA section 303(d) List. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 130276, Fecal Coliform
Region 3     
Zaca Lake
 
LOE ID: 150416
 
Pollutant: Fecal Coliform
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Non-Contact Recreation
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed data for Zaca Lake to determine beneficial use support and the results are as follows: 0 of the 1 samples exceeded the water quality threshold for Coliform, Fecal. The water quality threshold is based on a 10% exceedance rate that is calculated for a 30-Day peroid.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for non-contact water recreation uses (Section 3.3.2. Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states the following: Fecal coliform concentration, based on a minimum of not less than five samples for any 30-day period, shall not exceed a log mean of 2000/100 mL, nor shall more than ten percent of samples collected during any 30-day period exceed 4000/100 mL.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site(s), station(s): 314ZCALK2
Temporal Representation: The samples were collected between the days of 2017-05-18 and 2017-05-18 .
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
 
DECISION ID
128283
Region 3     
Zaca Lake
 
Pollutant: Nitrate
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.

Six lines of evidence are available in the administrative record to assess this pollutant. Zero of the two samples exceed the water quality objective for Municipal and Domestic Supply or the evaluation guideline for aquatic life. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of the two samples exceed the water quality objective for Municipal and Domestic Supply or the evaluation guideline for aquatic life and this does not exceed the allowable frequency listed in Table 3.1 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 128283, Nitrate
Region 3     
Zaca Lake
 
LOE ID: 172613
 
Pollutant: Nitrogen, Nitrate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nitrate as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: All inland surface waters, enclosed bays, and estuaries shall not contain concentrations of inorganic chemicals in excess of the maximum contaminant levels for primary drinking water standards specified in California Code of Regulations, Title 22, Division 4, Chapter 15, Sections 64431 and 64433.2.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: The California Maximum Contaminant Level for nitrate (as N) 10.0 mg/L (California Code of Regulations, Title 22).
Guideline Reference: California MCLs - Title 17 and Title 22 documents for 2019 - California Regulations Related to Drinking Water
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 128283, Nitrate
Region 3     
Zaca Lake
 
LOE ID: 172743
 
Pollutant: Nitrogen, Nitrate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nitrate as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain biostimulatory substances in concentrations that promote aquatic growths to the extent that such growths cause nuisance or adversely affect beneficial uses (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: Technical approach to develop nutrient numeric endpoints for California, Tetra Tech, June 2006. The Central Coast Region numeric target for maximum nitrate concentration is based on the Tetra Tech NNE (Nutrient Numeric Endpoint) Model and CCAMP data for 193 sites, monitored monthly for at least 1 year between January 1998 and December 2006. The model numeric target for aquatic life habitats in the Central Coast Region is 1.0 mg/L Nitrate as N.
Guideline Reference: Central Coast RegionTechnical Paper: Interpreting Narrative Objectives for Biostimulatory Substances for California Central Coast Waters. This method uses the Technical Approach for Developing California Nutrient Numeric Endpoints.
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 128283, Nitrate
Region 3     
Zaca Lake
 
LOE ID: 172900
 
Pollutant: Nitrogen, Nitrate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nitrate as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain biostimulatory substances in concentrations that promote aquatic growths to the extent that such growths cause nuisance or adversely affect beneficial uses (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: Technical approach to develop nutrient numeric endpoints for California, Tetra Tech, June 2006. The Central Coast Region numeric target for maximum nitrate concentration is based on the Tetra Tech NNE (Nutrient Numeric Endpoint) Model and CCAMP data for 193 sites, monitored monthly for at least 1 year between January 1998 and December 2006. The model numeric target for aquatic life habitats in the Central Coast Region is 1.0 mg/L Nitrate as N.
Guideline Reference: Central Coast RegionTechnical Paper: Interpreting Narrative Objectives for Biostimulatory Substances for California Central Coast Waters. This method uses the Technical Approach for Developing California Nutrient Numeric Endpoints.
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 128283, Nitrate
Region 3     
Zaca Lake
 
LOE ID: 172738
 
Pollutant: Nitrogen, Nitrate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nitrate as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain biostimulatory substances in concentrations that promote aquatic growths to the extent that such growths cause nuisance or adversely affect beneficial uses (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: Technical approach to develop nutrient numeric endpoints for California, Tetra Tech, June 2006. The Central Coast Region numeric target for maximum nitrate concentration is based on the Tetra Tech NNE (Nutrient Numeric Endpoint) Model and CCAMP data for 193 sites, monitored monthly for at least 1 year between January 1998 and December 2006. The model numeric target for aquatic life habitats in the Central Coast Region is 1.0 mg/L Nitrate as N.
Guideline Reference: Central Coast RegionTechnical Paper: Interpreting Narrative Objectives for Biostimulatory Substances for California Central Coast Waters. This method uses the Technical Approach for Developing California Nutrient Numeric Endpoints.
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 128283, Nitrate
Region 3     
Zaca Lake
 
LOE ID: 172488
 
Pollutant: Nitrogen, Nitrate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nitrate as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: All inland surface waters, enclosed bays, and estuaries shall not contain concentrations of inorganic chemicals in excess of the maximum contaminant levels for primary drinking water standards specified in California Code of Regulations, Title 22, Division 4, Chapter 15, Sections 64431 and 64433.2.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: The California Maximum Contaminant Level for nitrate (as N) 10.0 mg/L (California Code of Regulations, Title 22).
Guideline Reference: California MCLs - Title 17 and Title 22 documents for 2019 - California Regulations Related to Drinking Water
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 128283, Nitrate
Region 3     
Zaca Lake
 
LOE ID: 172611
 
Pollutant: Nitrogen, Nitrate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nitrate as N.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain biostimulatory substances in concentrations that promote aquatic growths to the extent that such growths cause nuisance or adversely affect beneficial uses (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: Technical approach to develop nutrient numeric endpoints for California, Tetra Tech, June 2006. The Central Coast Region numeric target for maximum nitrate concentration is based on the Tetra Tech NNE (Nutrient Numeric Endpoint) Model and CCAMP data for 193 sites, monitored monthly for at least 1 year between January 1998 and December 2006. The model numeric target for aquatic life habitats in the Central Coast Region is 1.0 mg/L Nitrate as N.
Guideline Reference: Central Coast RegionTechnical Paper: Interpreting Narrative Objectives for Biostimulatory Substances for California Central Coast Waters. This method uses the Technical Approach for Developing California Nutrient Numeric Endpoints.
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
 
DECISION ID
114948
Region 3     
Zaca Lake
 
Pollutant: Oxygen, Dissolved
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

Six lines of evidence are available in the administrative record to assess this pollutant.

Zero of two samples exceed the water quality objective for cold freshwater habitat (Basin Plan) and zero of two samples exceed the water quality objective for fish spawning (Basin Plan). Zero of two samples exceed the water quality objective for warm freshwater habitat (Basin Plan).

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the section 303(d) List in the Water Quality Limited Segments category. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. No samples exceed the objective for cold freshwater habitat, fish spawning, or warm freshwater habitat. These do not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) List. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 114948, Oxygen, Dissolved
Region 3     
Zaca Lake
 
LOE ID: 175654
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Fish Spawning
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Oxygen, Dissolved.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The dissolved oxygen concentration shall not be reduced below 7.0 mg/l at any time (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114948, Oxygen, Dissolved
Region 3     
Zaca Lake
 
LOE ID: 175391
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Oxygen, Dissolved.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The dissolved oxygen concentration shall not be reduced below 5.0 mg/l at any time (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114948, Oxygen, Dissolved
Region 3     
Zaca Lake
 
LOE ID: 175434
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Oxygen, Dissolved.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The dissolved oxygen concentration shall not be reduced below 7.0 mg/l at any time (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114948, Oxygen, Dissolved
Region 3     
Zaca Lake
 
LOE ID: 175397
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Fish Spawning
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Oxygen, Dissolved.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The dissolved oxygen concentration shall not be reduced below 7.0 mg/l at any time (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114948, Oxygen, Dissolved
Region 3     
Zaca Lake
 
LOE ID: 175680
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Oxygen, Dissolved.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The dissolved oxygen concentration shall not be reduced below 7.0 mg/l at any time (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114948, Oxygen, Dissolved
Region 3     
Zaca Lake
 
LOE ID: 175361
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Oxygen, Dissolved.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The dissolved oxygen concentration shall not be reduced below 5.0 mg/l at any time (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
 
DECISION ID
126256
Region 3     
Zaca Lake
 
Pollutant: Temperature, water
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the Clean Water Act (CWA) section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

A total of two lines of evidence are available in the administrative record to assess this pollutant. A total of zero of two samples exceed the evaluation guideline (Moyle 1976) applied to protect the cold freshwater habitat beneficial use. The readily available data and information are insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.

After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. A total of zero of two samples exceed the evaluation guideline applied to protect the cold freshwater habitat beneficial use and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 126256, Temperature, water
Region 3     
Zaca Lake
 
LOE ID: 216698
 
Pollutant: Temperature, water
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Temperature.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Natural receiving water temperature of intrastate waters shall not be altered unless it can be demonstrated to the satisfaction of the Regional Board that such alteration in temperature does not adversely affect beneficial uses (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: The optimum range for growth and completion of most life stages of rainbow trout is 13-21 degrees Celsius (Moyle 1976).
Guideline Reference: Inland Fishes of California
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 126256, Temperature, water
Region 3     
Zaca Lake
 
LOE ID: 216976
 
Pollutant: Temperature, water
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Temperature.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Natural receiving water temperature of intrastate waters shall not be altered unless it can be demonstrated to the satisfaction of the Regional Board that such alteration in temperature does not adversely affect beneficial uses (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: The optimum range for growth and completion of most life stages of rainbow trout is 13-21 degrees Celsius (Moyle 1976).
Guideline Reference: Inland Fishes of California
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
 
DECISION ID
114950
Region 3     
Zaca Lake
 
Pollutant: Turbidity
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the Clean Water Act (CWA) section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

A total of four lines of evidence are available in the administrative record to assess this pollutant. A total of one of two samples exceed the evaluation guideline for cold freshwater habitat (Sigler et al. 1984) and zero of two samples exceed the evaluation guideline for warm freshwater habitat (Shoup, D.E. and Wahl D.H., 2009) used to interpret the water quality objectives for the aquatic life beneficial uses. The readily available data and information are insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.

After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. A total of one of two samples exceed the evaluation guideline for cold freshwater habitat and zero of two samples exceed the evaluation guideline for warm freshwater habitat and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 114950, Turbidity
Region 3     
Zaca Lake
 
LOE ID: 181999
 
Pollutant: Turbidity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Turbidity.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall be free of changes in turbidity that cause nuisance or adversely affect beneficial uses (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: Turbidities of 40 NTU or greater can cause a reduced foraging efficiency and a shift in prey selection in piscivorous fish (largemouth bass) due to interference with their ability to find prey (Shoup, D.E. and Wahl D.H., 2009).
Guideline Reference: The Effects of Turbidity on Prey Selection by Piscivorous Largemouth Bass
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114950, Turbidity
Region 3     
Zaca Lake
 
LOE ID: 183039
 
Pollutant: Turbidity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Turbidity.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall be free of changes in turbidity that cause nuisance or adversely affect beneficial uses (Water Quality Control Plan, Central Coast Basin).
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: Turbidities of 40 NTU or greater can cause a reduced foraging efficiency and a shift in prey selection in piscivorous fish (largemouth bass) due to interference with their ability to find prey (Shoup, D.E. and Wahl D.H., 2009).
Guideline Reference: The Effects of Turbidity on Prey Selection by Piscivorous Largemouth Bass
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114950, Turbidity
Region 3     
Zaca Lake
 
LOE ID: 183205
 
Pollutant: Turbidity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Turbidity.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall be free of changes in turbidity that cause nuisance or adversely affect beneficial uses. (Basin Plan)
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: Turbidities of 25 NTU or greater can cause a reduction in juvenile salmonid growth due to interference with their ability to find food (Sigler et al. 1984).
Guideline Reference: Effects of chronic turbidity on density and growth of steelheads and coho salmon. Transactions of the American Fisheries Society 113:142-150
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114950, Turbidity
Region 3     
Zaca Lake
 
LOE ID: 182070
 
Pollutant: Turbidity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Turbidity.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall be free of changes in turbidity that cause nuisance or adversely affect beneficial uses. (Basin Plan)
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline: Turbidities of 25 NTU or greater can cause a reduction in juvenile salmonid growth due to interference with their ability to find food (Sigler et al. 1984).
Guideline Reference: Effects of chronic turbidity on density and growth of steelheads and coho salmon. Transactions of the American Fisheries Society 113:142-150
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
 
DECISION ID
114949
Region 3     
Zaca Lake
 
Pollutant: pH
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

Ten lines of evidence is available in the administrative record to assess this pollutant. Two of the 2 samples exceed the maximum pH water quality objective for Agriculture Supply, Cold and Warm Freshwater Habitat, Municipal and Domestic Supply, Contact and Non-contact Recreation beneficial uses. This sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is supported and a minimum of five exceedances is needed to determine if beneficial uses are not supported using Table 3.2 of the Listing Policy. Therefore, the use support rating is set to 'insufficient information'.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the section 303(d) List in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Two of the 2 samples exceed the maximum pH water quality objective for Agriculture Supply, Cold and Warm Freshwater Habitat, Municipal and Domestic Supply, Contact and Non-contact Recreation beneficial uses and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) List. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 114949, pH
Region 3     
Zaca Lake
 
LOE ID: 179763
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Non-Contact Recreation
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for non-contact water recreation (Section 3.3.2 Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states that the pH value shall neither be depressed below 6.5 nor raised above 8.3.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114949, pH
Region 3     
Zaca Lake
 
LOE ID: 179883
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for water contact recreation (Section 3.3.2 Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states that the pH value shall neither be depressed below 6.5 nor raised above 8.3.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114949, pH
Region 3     
Zaca Lake
 
LOE ID: 179958
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for cold fresh water habitat (Section 3.3.2 Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states that the pH value shall neither be depressed below 7.0 nor raised above 8.5.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114949, pH
Region 3     
Zaca Lake
 
LOE ID: 179315
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for water contact recreation (Section 3.3.2 Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states that the pH value shall neither be depressed below 6.5 nor raised above 8.3.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114949, pH
Region 3     
Zaca Lake
 
LOE ID: 179780
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Non-Contact Recreation
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for non-contact water recreation (Section 3.3.2 Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states that the pH value shall neither be depressed below 6.5 nor raised above 8.3.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114949, pH
Region 3     
Zaca Lake
 
LOE ID: 179353
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for cold fresh water habitat (Section 3.3.2 Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states that the pH value shall neither be depressed below 7.0 nor raised above 8.5.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114949, pH
Region 3     
Zaca Lake
 
LOE ID: 179938
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for municipal and domestic supply (Section 3.3.2 Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states that the pH value shall neither be depressed below 6.5 nor raised above 8.3.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114949, pH
Region 3     
Zaca Lake
 
LOE ID: 179390
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for municipal and domestic supply (Section 3.3.2 Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states that the pH value shall neither be depressed below 6.5 nor raised above 8.3.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114949, pH
Region 3     
Zaca Lake
 
LOE ID: 179939
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for warm fresh water habitat (Section 3.3.2 Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states that the pH value shall neither be depressed below 7.0 nor raised above 8.5.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK2)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 114949, pH
Region 3     
Zaca Lake
 
LOE ID: 179340
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP RWB3 CCAMP Lakes Study data for Zaca Lake to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Habitat, Tissue, Water data for the 2020/2022 integrated report in Region 3.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan, Central Coast Basin objective for warm fresh water habitat (Section 3.3.2 Objectives for All Inland Surface Waters, Enclosed Bays, and Estuaries) states that the pH value shall neither be depressed below 7.0 nor raised above 8.5.
Objective/Criterion Reference: Water Quality Control Plan for the Central Coastal Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (314ZCALK1)
Temporal Representation: The samples were collected between the dates of 2017-05-18 and 2017-05-18
Environmental Conditions:
QAPP Information: SWAMP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program