Final California 2020 Integrated Report (303(d) List/305(b) Report)

Supporting Information

Regional Board 9 - San Diego Region

Water Body Name: Buena Creek
Water Body ID: CAR9043200020050630113820
Water Body Type: River & Stream
 
DECISION ID
132046
Region 9     
Buena Creek
 
Pollutant: Nitrogen
Final Listing Decision: Do Not Delist from 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Sources: A Source Unknown
Expected TMDL Completion Date: 2023
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for removal from the CWA section 303(d) List under section 4.1 of the Listing Policy. Under this section a single line of evidence is necessary to assess listing status.

Three lines of evidence are available in the administrative record to assess pollutant. Six of the six samples exceed the OBJECTIVE.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against removing this water segment-pollutant combination from the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Six of six samples exceeded the OBJECTIVE and this exceeds the allowable frequency listed in Table 4.1 of the Listing Policy.
4. Pursuant to section 4.11 of the Listing Policy, no additional data and information are available indicating that standards are met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be removed from the section 303(d) list because applicable water quality standards for the pollutant are being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 132046, Nitrogen
Region 9     
Buena Creek
 
LOE ID: 144022
 
Pollutant:
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use:
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Nitrogen, Total.
Data Reference:
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Concentrations of nitrogen and phosphorus, by themselves or in combination with other nutrients, shall be maintained at levels below those which stimulate algae and emergent plant growth. A desired goal in order to prevent plant nuisance in streams and other flowing waters appears to be 0.1 mg/L total P. Analogous threshold values have not been set for nitrogen compounds; however, natural ratios of nitrogen to phosphorus are to be determined by surveillance and monitoring and upheld. If data are lacking, a ratio of N:P = 10:1, on a weight to weight basis shall be used (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference:
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s):
 
Line of Evidence (LOE) for Decision ID 132046, Nitrogen
Region 9     
Buena Creek
 
LOE ID: 144024
 
Pollutant: Total Nitrogen as N
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Nitrogen, Total.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Concentrations of nitrogen and phosphorus, by themselves or in combination with other nutrients, shall be maintained at levels below those which stimulate algae and emergent plant growth. A desired goal in order to prevent plant nuisance in streams and other flowing waters appears to be 0.1 mg/L total P. Analogous threshold values have not been set for nitrogen compounds; however, natural ratios of nitrogen to phosphorus are to be determined by surveillance and monitoring and upheld. If data are lacking, a ratio of N:P = 10:1, on a weight to weight basis shall be used (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 132046, Nitrogen
Region 9     
Buena Creek
 
LOE ID: 6542
 
Pollutant: Total Nitrogen as N
LOE Subgroup: Pollution
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: Fixed station physical/chemical monitoring (conventional pollutants only)
Data Used to Assess Water Quality: All four samples collected at Buena Creek show excessive nitrogen concentrations according to results in California's Surface Water Ambient Monitoring Program Report, 2007.
Water samples were collected in March, April, June and September 2002.
Data Reference: Water Quality Control Plan for the San Diego Basin
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Water bodies shall not contain biostimulatory substances in concentrations that promote aquatic growth to the extent that such growths cause nuisance or adversely affect beneficial uses (RWQCB, 2007).
A desired goal in order to prevent plant nuisance in streams and other flowing waters appears to be 0.1 mg/L total phosphorus, P. These values are not to be exceeded more than 10% of the time unless studies of the specific water body in question clearly show that water quality objective changes are permissible and changes are approved by the Regional Board. Analogous threshold values have not been set for nitrogen compounds; however, natural ratios of nitrogen to phosphorus are to be determined by surveillance and monitoring and upheld. If data are lacking, a ratio of N:P = 10:1, on a weight to weight basis shall be used (RWQCB, 2007).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference: Water Quality Control Plan for the San Diego Basin
 
Spatial Representation: Water samples were collected at Buena Creek station 904CBBUR1; (Latitude 33.1725, Longitude -117.2082).
Temporal Representation: Water samples were collected in March, April, June and September 2002.
Environmental Conditions:
QAPP Information: Quality control for the chemical analysis portion of this study was conducted in accordance with the California's Surface Water Ambient Monitoring Program.
QAPP Information Reference(s):
 
 
DECISION ID
111627
Region 9     
Buena Creek
 
Pollutant: Phosphorus
Final Listing Decision: Do Not Delist from 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Sources: A Source Unknown
Expected TMDL Completion Date: 2023
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for removal from the CWA section 303(d) List under section 4.1 of the Listing Policy. Under this section a single line of evidence is necessary to assess listing status.

Three lines of evidence are available in the administrative record to assess pollutant. Five of the six samples exceed the threshold.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against removing this water segment-pollutant combination from the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Five of six samples exceeded the thtreshold, and this exceeds the allowable frequency listed in Table 4.1 of the Listing Policy.
4. Pursuant to section 4.11 of the Listing Policy, no additional data and information are available indicating that standards are met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be removed from the section 303(d) list because applicable water quality standards for the pollutant are being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 111627, Phosphorus
Region 9     
Buena Creek
 
LOE ID: 6540
 
Pollutant: Phosphorus
LOE Subgroup: Pollution
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: Fixed station physical/chemical monitoring (conventional pollutants only)
Data Used to Assess Water Quality: Four of four samples collected at Buena Creek show excessive phosphorous concentrations according to results in California's Surface Water Ambient Monitoring Program, 2007. Samples were collected in March, April, June and September 2002.
Data Reference: Monitoring data for Region 9
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: From the Basin Plan: For inland surface waters-streams and other flowing waters, with all beneficial uses, the water quality objective for total phosphorus is 0.1 mg/L (RWQCB, 2007).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Water samples were collected at Buena Creek station 904CBBUR1; (Latitude 33.1725, Longitude -117.2082).
Temporal Representation: Samples were collected in March, April, June and September 2002.
Environmental Conditions:
QAPP Information: Quality control for the chemical analysis portion of this study was conducted in accordance with the California's Surface Water Ambient Monitoring Program.
QAPP Information Reference(s):
 
Line of Evidence (LOE) for Decision ID 111627, Phosphorus
Region 9     
Buena Creek
 
LOE ID: 145760
 
Pollutant: Phosphorus
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Phosphorus as P.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Concentrations of nitrogen and phosphorus, by themselves or in combination with other nutrients, shall be maintained at levels below those which stimulate algae and emergent plant growth. A desired goal in order to prevent plant nuisance in streams and other flowing waters appears to be 0.1 mg/L total P. Analogous threshold values have not been set for nitrogen compounds; however, natural ratios of nitrogen to phosphorus are to be determined by surveillance and monitoring and upheld. If data are lacking, a ratio of N:P = 10:1, on a weight to weight basis shall be used (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111627, Phosphorus
Region 9     
Buena Creek
 
LOE ID: 145684
 
Pollutant: Phosphorus
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Phosphorus as P.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Concentrations of nitrogen and phosphorus, by themselves or in combination with other nutrients, shall be maintained at levels below those which stimulate algae and emergent plant growth. A desired goal in order to prevent plant nuisance in streams and other flowing waters appears to be 0.1 mg/L total P. Analogous threshold values have not been set for nitrogen compounds; however, natural ratios of nitrogen to phosphorus are to be determined by surveillance and monitoring and upheld. If data are lacking, a ratio of N:P = 10:1, on a weight to weight basis shall be used (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111633
Region 9     
Buena Creek
 
Pollutant: Alkalinity as CaCO3
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111633, Alkalinity as CaCO3
Region 9     
Buena Creek
 
LOE ID: 139712
 
Pollutant: Alkalinity as CaCO3
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Alkalinity as CaCO3.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: All waters shall be maintained free of toxic substances in concentrations that are toxic to, or produce detrimental physiological responses in, human, plant, animal, or aquatic life (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The CCC of 20mg/L is a minimum value except where alkalinity is naturally lower, in which case the criterion cannot be lower than 25% of the natural level (USEPA National Recommended Water Quality Criteria Aquatic Life)
Guideline Reference: National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Office of Science and Technology
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111633, Alkalinity as CaCO3
Region 9     
Buena Creek
 
LOE ID: 139520
 
Pollutant: Alkalinity as CaCO3
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Alkalinity as CaCO3.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: All waters shall be maintained free of toxic substances in concentrations that are toxic to, or produce detrimental physiological responses in, human, plant, animal, or aquatic life (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The CCC of 20mg/L is a minimum value except where alkalinity is naturally lower, in which case the criterion cannot be lower than 25% of the natural level (USEPA National Recommended Water Quality Criteria Aquatic Life)
Guideline Reference: National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Office of Science and Technology
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
127802
Region 9     
Buena Creek
 
Pollutant: Ammonia
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 127802, Ammonia
Region 9     
Buena Creek
 
LOE ID: 73080
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Ammonia As N, Total.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Basin Plan: No individual chemical or combination of chemicals shall be present in concentrations that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: EPA's Lifetime Health advisory level for total ammonia is 30.0 mg/L as stated on page 8 of the 2006 edition of the drinking water standards and health advisories. This Advisory Level is defined as "the concentration of a chemical in drinking water that is not expected to cause any adverse noncarcinogenic effects for up to ten days of exposure."
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected on a single day 6/30/2003.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 127802, Ammonia
Region 9     
Buena Creek
 
LOE ID: 185335
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Ammonia as N.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Total Ammonia criterion continuous concentration (expressed as a 30-day average) to protect aquatic life in freshwater is Temperature and pH dependent, and was calculated according to the formula listed in the Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013 document.
Objective/Criterion Reference: Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 127802, Ammonia
Region 9     
Buena Creek
 
LOE ID: 185072
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Ammonia as N.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Total Ammonia criterion continuous concentration (expressed as a 30-day average) to protect aquatic life in freshwater is Temperature and pH dependent, and was calculated according to the formula listed in the Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013 document.
Objective/Criterion Reference: Aquatic Life Ambient Water Quality Criteria for Ammonia - Freshwater 2013
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
115508
Region 9     
Buena Creek
 
Pollutant: Ammonia (Unionized)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of the available data and information, SWRCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because it cannot be determined if applicable water quality standards are not being exceeded.
 
 
Line of Evidence (LOE) for Decision ID 115508, Ammonia (Unionized)
Region 9     
Buena Creek
 
LOE ID: 185327
 
Pollutant: Ammonia (Unionized)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support, and the results are as follows: 0 of the 0 samples exceeded the evaluation guideline for Ammonia as N, Unionized. Although a total of 1 samples were collected, 1 of these samples were not included in the assessment because the laboratory data reporting limit(s) was above the water quality threshold and therefore the results could not be quantified with the level of certainty required by the Listing Policy Section 6.1.5.5.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The discharge of wastes shall not cause concentrations of un-ionized ammonia (NH3) to exceed 0.025 mg/l (as N) in inland surface waters, enclosed bays and estuaries and coastal lagoons (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049).
Temporal Representation: Date for this waterbody was collected over the date range 2014-07-09 to 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111618
Region 9     
Buena Creek
 
Pollutant: Arsenic
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111618, Arsenic
Region 9     
Buena Creek
 
LOE ID: 139965
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Arsenic.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for arsenic is 0.01 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111618, Arsenic
Region 9     
Buena Creek
 
LOE ID: 140024
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Arsenic.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The dissolved arsenic criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater for dissolved arsenic is 0.150 mg/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111618, Arsenic
Region 9     
Buena Creek
 
LOE ID: 140404
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Arsenic.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The dissolved arsenic criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater for dissolved arsenic is 0.150 mg/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111618, Arsenic
Region 9     
Buena Creek
 
LOE ID: 140385
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Arsenic.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for arsenic is 0.01 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111618, Arsenic
Region 9     
Buena Creek
 
LOE ID: 140405
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Arsenic.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The dissolved arsenic criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater for dissolved arsenic is 0.150 mg/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111618, Arsenic
Region 9     
Buena Creek
 
LOE ID: 140226
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Arsenic.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The dissolved arsenic criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater for dissolved arsenic is 0.150 mg/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111618, Arsenic
Region 9     
Buena Creek
 
LOE ID: 140046
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Arsenic.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for arsenic is 0.01 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111618, Arsenic
Region 9     
Buena Creek
 
LOE ID: 140176
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Arsenic.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for arsenic is 0.01 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111619
Region 9     
Buena Creek
 
Pollutant: Cadmium
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 111619, Cadmium
Region 9     
Buena Creek
 
LOE ID: 140838
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Cadmium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for cadmium is 0.005 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111619, Cadmium
Region 9     
Buena Creek
 
LOE ID: 140652
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Cadmium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for cadmium is 0.005 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111619, Cadmium
Region 9     
Buena Creek
 
LOE ID: 140554
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Cadmium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for cadmium is 0.005 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111619, Cadmium
Region 9     
Buena Creek
 
LOE ID: 140837
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Cadmium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111619, Cadmium
Region 9     
Buena Creek
 
LOE ID: 73082
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Cadmium.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for cadmium is 0.005 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 111619, Cadmium
Region 9     
Buena Creek
 
LOE ID: 73081
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Cadmium.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 111619, Cadmium
Region 9     
Buena Creek
 
LOE ID: 140815
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Cadmium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for cadmium is 0.005 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111619, Cadmium
Region 9     
Buena Creek
 
LOE ID: 140920
 
Pollutant: Cadmium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Cadmium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111620
Region 9     
Buena Creek
 
Pollutant: Chloride
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111620, Chloride
Region 9     
Buena Creek
 
LOE ID: 141333
 
Pollutant: Chloride
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Agricultural Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Chloride.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Chloride water quality threshold in this HSA is 250 mg/L, and this concentration is not to be exceeded more than 10% of the time during any one year period (Basin Plan, Table 3-2).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111620, Chloride
Region 9     
Buena Creek
 
LOE ID: 140819
 
Pollutant: Chloride
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Chloride.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Chloride water quality threshold in this HSA is 250 mg/L, and this concentration is not to be exceeded more than 10% of the time during any one year period (Basin Plan, Table 3-2).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111620, Chloride
Region 9     
Buena Creek
 
LOE ID: 141043
 
Pollutant: Chloride
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Chloride.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Chloride water quality threshold in this HSA is 250 mg/L, and this concentration is not to be exceeded more than 10% of the time during any one year period (Basin Plan, Table 3-2).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111620, Chloride
Region 9     
Buena Creek
 
LOE ID: 141428
 
Pollutant: Chloride
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Agricultural Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Chloride.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Chloride water quality threshold in this HSA is 250 mg/L, and this concentration is not to be exceeded more than 10% of the time during any one year period (Basin Plan, Table 3-2).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111620, Chloride
Region 9     
Buena Creek
 
LOE ID: 140804
 
Pollutant: Chloride
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Chloride.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Chloride water quality threshold in this HSA is 250 mg/L, and this concentration is not to be exceeded more than 10% of the time during any one year period (Basin Plan, Table 3-2).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111620, Chloride
Region 9     
Buena Creek
 
LOE ID: 140817
 
Pollutant: Chloride
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Chloride.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Chloride water quality threshold in this HSA is 250 mg/L, and this concentration is not to be exceeded more than 10% of the time during any one year period (Basin Plan, Table 3-2).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111634
Region 9     
Buena Creek
 
Pollutant: Chromium
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111634, Chromium
Region 9     
Buena Creek
 
LOE ID: 141396
 
Pollutant: Chromium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Chromium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111634, Chromium
Region 9     
Buena Creek
 
LOE ID: 141127
 
Pollutant: Chromium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Chromium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for total chromium is 0.05 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111634, Chromium
Region 9     
Buena Creek
 
LOE ID: 141379
 
Pollutant: Chromium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Chromium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for total chromium is 0.05 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111634, Chromium
Region 9     
Buena Creek
 
LOE ID: 141380
 
Pollutant: Chromium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Chromium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111634, Chromium
Region 9     
Buena Creek
 
LOE ID: 141172
 
Pollutant: Chromium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Chromium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for total chromium is 0.05 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111634, Chromium
Region 9     
Buena Creek
 
LOE ID: 141419
 
Pollutant: Chromium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Chromium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for total chromium is 0.05 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111621
Region 9     
Buena Creek
 
Pollutant: Copper
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 111621, Copper
Region 9     
Buena Creek
 
LOE ID: 73084
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Copper.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 111621, Copper
Region 9     
Buena Creek
 
LOE ID: 73085
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Copper.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary MCL for copper is 1.0 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Secondary Maximum Contaminant Levels and Compliance. CCR Title 22 section 64449.
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 111621, Copper
Region 9     
Buena Creek
 
LOE ID: 141755
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Copper.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary MCL for copper is 1.0 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111621, Copper
Region 9     
Buena Creek
 
LOE ID: 141588
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Copper.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary MCL for copper is 1.0 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111621, Copper
Region 9     
Buena Creek
 
LOE ID: 141806
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Copper.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary MCL for copper is 1.0 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111621, Copper
Region 9     
Buena Creek
 
LOE ID: 141774
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Copper.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Secondary MCL for copper is 1.0 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111621, Copper
Region 9     
Buena Creek
 
LOE ID: 141478
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Copper.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111621, Copper
Region 9     
Buena Creek
 
LOE ID: 141514
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Copper.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111622
Region 9     
Buena Creek
 
Pollutant: Lead
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 111622, Lead
Region 9     
Buena Creek
 
LOE ID: 73090
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Lead.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for Lead is 0.015 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 111622, Lead
Region 9     
Buena Creek
 
LOE ID: 73089
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Lead.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 111622, Lead
Region 9     
Buena Creek
 
LOE ID: 143256
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Lead.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for lead is .015 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111622, Lead
Region 9     
Buena Creek
 
LOE ID: 143393
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Lead.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111622, Lead
Region 9     
Buena Creek
 
LOE ID: 143209
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Lead.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for lead is .015 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111622, Lead
Region 9     
Buena Creek
 
LOE ID: 143191
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Lead.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for lead is .015 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111622, Lead
Region 9     
Buena Creek
 
LOE ID: 143351
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Lead.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111622, Lead
Region 9     
Buena Creek
 
LOE ID: 142935
 
Pollutant: Lead
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Lead.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Maximum Contaminant Level for lead is .015 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111623
Region 9     
Buena Creek
 
Pollutant: Nickel
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111623, Nickel
Region 9     
Buena Creek
 
LOE ID: 143763
 
Pollutant: Nickel
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nickel.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nickel is 0.1 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111623, Nickel
Region 9     
Buena Creek
 
LOE ID: 143542
 
Pollutant: Nickel
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nickel.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111623, Nickel
Region 9     
Buena Creek
 
LOE ID: 143740
 
Pollutant: Nickel
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nickel.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nickel is 0.1 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111623, Nickel
Region 9     
Buena Creek
 
LOE ID: 143645
 
Pollutant: Nickel
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nickel.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nickel is 0.1 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111623, Nickel
Region 9     
Buena Creek
 
LOE ID: 143528
 
Pollutant: Nickel
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nickel.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111623, Nickel
Region 9     
Buena Creek
 
LOE ID: 143698
 
Pollutant: Nickel
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nickel.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nickel is 0.1 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111624
Region 9     
Buena Creek
 
Pollutant: Nitrate/Nitrite (Nitrite + Nitrate as N)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111624, Nitrate/Nitrite (Nitrite + Nitrate as N)
Region 9     
Buena Creek
 
LOE ID: 143773
 
Pollutant: Nitrate/Nitrite (Nitrite + Nitrate as N)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Nitrate + Nitrite as N.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nitrate + nitrite (as N) is 10.0 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111624, Nitrate/Nitrite (Nitrite + Nitrate as N)
Region 9     
Buena Creek
 
LOE ID: 143776
 
Pollutant: Nitrate/Nitrite (Nitrite + Nitrate as N)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nitrate + Nitrite as N.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nitrate + nitrite (as N) is 10.0 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
127798
Region 9     
Buena Creek
 
Pollutant: Nitrogen, Nitrite
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 127798, Nitrogen, Nitrite
Region 9     
Buena Creek
 
LOE ID: 143859
 
Pollutant: Nitrogen, Nitrite
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nitrite as N.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nitrite (as N) is 1.0 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 127798, Nitrogen, Nitrite
Region 9     
Buena Creek
 
LOE ID: 143900
 
Pollutant: Nitrogen, Nitrite
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Nitrite as N.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nitrite (as N) is 1.0 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Title 22. Division 4. Chapter 15. Sections 64400 et seq. California Code of Regulations
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 127798, Nitrogen, Nitrite
Region 9     
Buena Creek
 
LOE ID: 73093
 
Pollutant: Nitrogen, Nitrite
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 2
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 2 samples exceed the criterion for Nitrite as N.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nitrite (as N) is 1.0 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 6/30/2003-9/3/2003.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
111625
Region 9     
Buena Creek
 
Pollutant: Oxygen, Dissolved
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111625, Oxygen, Dissolved
Region 9     
Buena Creek
 
LOE ID: 144490
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Oxygen, Dissolved.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Dissolved oxygen levels shall not be less than 5.0 mg/l in inland surface waters with the WARM beneficial use designated (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111625, Oxygen, Dissolved
Region 9     
Buena Creek
 
LOE ID: 144764
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Oxygen, Dissolved.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Dissolved oxygen levels shall not be less than 5.0 mg/l in inland surface waters with the WARM beneficial use designated (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111628
Region 9     
Buena Creek
 
Pollutant: Selenium
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111628, Selenium
Region 9     
Buena Creek
 
LOE ID: 146207
 
Pollutant: Selenium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Selenium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California MCL for Selenium is .05 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111628, Selenium
Region 9     
Buena Creek
 
LOE ID: 146339
 
Pollutant: Selenium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Selenium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California MCL for Selenium is .05 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111628, Selenium
Region 9     
Buena Creek
 
LOE ID: 146456
 
Pollutant: Selenium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Selenium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The selenium criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater is 0.005 mg/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111628, Selenium
Region 9     
Buena Creek
 
LOE ID: 146452
 
Pollutant: Selenium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Selenium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California MCL for Selenium is .05 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111628, Selenium
Region 9     
Buena Creek
 
LOE ID: 146608
 
Pollutant: Selenium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Selenium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California MCL for Selenium is .05 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111628, Selenium
Region 9     
Buena Creek
 
LOE ID: 146322
 
Pollutant: Selenium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Selenium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The selenium criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater is 0.005 mg/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111628, Selenium
Region 9     
Buena Creek
 
LOE ID: 146203
 
Pollutant: Selenium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Selenium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The selenium criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater is 0.005 mg/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111628, Selenium
Region 9     
Buena Creek
 
LOE ID: 146700
 
Pollutant: Selenium
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Selenium.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The selenium criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater is 0.005 mg/L (California Toxics Rule, 2000).
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
127440
Region 9     
Buena Creek
 
Pollutant: Specific Conductivity
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 127440, Specific Conductivity
Region 9     
Buena Creek
 
LOE ID: 146802
 
Pollutant: Specific Conductivity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for SpecificConductivity.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Table 64449-A of section 64449 of Title 22 of the California Code of Regulations (Secondary Maximum Contaminant Levels, Consumer Acceptance Limits) which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Secondary MCL for specific conductance is 900 uS/cm (Title 22 California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 127440, Specific Conductivity
Region 9     
Buena Creek
 
LOE ID: 146742
 
Pollutant: Specific Conductivity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for SpecificConductivity.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Table 64449-A of section 64449 of Title 22 of the California Code of Regulations (Secondary Maximum Contaminant Levels, Consumer Acceptance Limits) which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Secondary MCL for specific conductance is 900 uS/cm (Title 22 California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111630
Region 9     
Buena Creek
 
Pollutant: Toxicity
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111630, Toxicity
Region 9     
Buena Creek
 
LOE ID: 134693
 
Pollutant: Toxicity
LOE Subgroup: Toxicity
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: TOXICITY TESTING
Data Used to Assess Water Quality: 0 of the 1 samples collected by SMC Regional Watershed Monitoring for Buena Creek exhibited toxicity. A sample may have multiple toxicity test results, but will only be counted once. A sample is defined as being collected on the same day, at the same location with the same lab sample ID (if provided). The following organisms and parameters were utilized for the toxicity tests: Ceriodaphnia dubia, for Survival, Ceriodaphnia dubia, for Young/female
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life. Compliance with this objective will be determined by use of indicator organisms, analyses of species diversity, population density, growth anomalies, bioassays of appropriate duration, or other appropriate methods as specified by the Regional Board.
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 station. Monitoring site: ( SMC04121 )
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09.
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111630, Toxicity
Region 9     
Buena Creek
 
LOE ID: 134723
 
Pollutant: Toxicity
LOE Subgroup: Toxicity
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: TOXICITY TESTING
Data Used to Assess Water Quality: 0 of the 1 samples collected by SMC Regional Watershed Monitoring for Buena Creek exhibited toxicity. A sample may have multiple toxicity test results, but will only be counted once. A sample is defined as being collected on the same day, at the same location with the same lab sample ID (if provided). The following organisms and parameters were utilized for the toxicity tests: Ceriodaphnia dubia, for Survival, Ceriodaphnia dubia, for Young/female
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life. Compliance with this objective will be determined by use of indicator organisms, analyses of species diversity, population density, growth anomalies, bioassays of appropriate duration, or other appropriate methods as specified by the Regional Board.
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 station. Monitoring site: ( SMC01049 )
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09.
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111631
Region 9     
Buena Creek
 
Pollutant: Turbidity
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111631, Turbidity
Region 9     
Buena Creek
 
LOE ID: 147660
 
Pollutant: Turbidity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Turbidity.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Turbidity water quality threshold in this HSA is 20 NTU, and this level is not to be exceeded more than 10% of the time during any one year period (Basin Plan, Table 3-2).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111631, Turbidity
Region 9     
Buena Creek
 
LOE ID: 147656
 
Pollutant: Turbidity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Turbidity.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Secondary California Maximum Contaminant Level for Turbidity is 5 NTU (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111631, Turbidity
Region 9     
Buena Creek
 
LOE ID: 147413
 
Pollutant: Turbidity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Turbidity.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Turbidity water quality threshold in this HSA is 20 NTU, and this level is not to be exceeded more than 10% of the time during any one year period (Basin Plan, Table 3-2).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111631, Turbidity
Region 9     
Buena Creek
 
LOE ID: 147570
 
Pollutant: Turbidity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Turbidity.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Secondary California Maximum Contaminant Level for Turbidity is 5 NTU (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111632
Region 9     
Buena Creek
 
Pollutant: Zinc
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2018)
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 111632, Zinc
Region 9     
Buena Creek
 
LOE ID: 73063
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Zinc.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual chemical or combination of chemicals shall be present in concentrations that adversely affect beneficial uses. (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The California Secondary MCL for zinc is 5.0 mg/L (Title 22 California Code of Regulations).
Guideline Reference: Secondary Maximum Contaminant Levels and Compliance. CCR Title 22 section 64449.
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 111632, Zinc
Region 9     
Buena Creek
 
LOE ID: 73064
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 7
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego DWM data for Buena Creek to determine beneficial use support and results are as follows: 0 of 7 samples exceed the criterion for Zinc.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected from 6/30/2003 through 6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 111632, Zinc
Region 9     
Buena Creek
 
LOE ID: 148044
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Zinc.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Secondary MCL for zinc is 5.0 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111632, Zinc
Region 9     
Buena Creek
 
LOE ID: 148047
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Zinc.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Secondary MCL for zinc is 5.0 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111632, Zinc
Region 9     
Buena Creek
 
LOE ID: 147855
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Zinc.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111632, Zinc
Region 9     
Buena Creek
 
LOE ID: 147830
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Zinc.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Secondary MCL for zinc is 5.0 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111632, Zinc
Region 9     
Buena Creek
 
LOE ID: 148194
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Dissolved
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Zinc.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion.
Objective/Criterion Reference: Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111632, Zinc
Region 9     
Buena Creek
 
LOE ID: 147815
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for Zinc.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the maximum contaminant levels specified in Title 22 of the California Code of Regulations which is incorporated by reference into this plan. (Water Quality Control Plan, San Diego Basin). The California Secondary MCL for zinc is 5.0 mg/L (Title 22 California Code of Regulations).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
111626
Region 9     
Buena Creek
 
Pollutant: pH
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 111626, pH
Region 9     
Buena Creek
 
LOE ID: 145422
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: In inland surface waters the pH shall not be depressed below 6.5 nor raised above 8.5.
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111626, pH
Region 9     
Buena Creek
 
LOE ID: 145108
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for pH.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: In inland surface waters the pH shall not be depressed below 6.5 nor raised above 8.5.
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
125934
Region 9     
Buena Creek
 
Pollutant: Benthic Community Effects
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Sources: A Source Unknown
Expected TMDL Completion Date: 2033
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Benthic Community Effects are being considered for placement on the CWA section 303(d) List under sections 3.9 of the Listing Policy. Under section 3.9, additional lines of evidence (LOEs) associating the Benthic Community Effects decision with a water or sediment concentration of pollutants other than benthic-macroinvertebrate bioassessment or habitat assessment LOEs are necessary to place a water body on the 303(d) List for Benthic Community Effects.

Two line(s) of evidence evaluating benthic-macroinvertebrate bioassessment data is/are available in the administrative record to assess this indicator. Two of three benthic-macroinvertebrate samples exceed the California Stream Condition Index (CSCI) impairment threshold. Once sample had insufficient BMI for inclusion in the decision and was not counted as an exceedance. These data indicate that the waterbody is likely impaired for Benthic Community Effects.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification for placing Benthic Community Effects in this waterbody segment on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Two of three benthic-macroinvertebrate bioassessment samples had CSCI scores below 0.79. Therefore, this water body is exceeding the water quality threshold for the protection of the COLD beneficial use.
4. Pursuant to section 3.9 of the Listing Policy, the water segment has associated pollutant(s) samples that exceed water quality objectives.
5. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 125934, Benthic Community Effects
Region 9     
Buena Creek
 
LOE ID: 215776
 
Pollutant: Benthic-Macroinvertebrate Bioassessments
LOE Subgroup: Population/Community Degradation
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 2
Number of Exceedances: 2
 
Data and Information Type: Benthic macroinvertebrate surveys
Data Used to Assess Water Quality: Water Board staff assessed data for SMC01049 to determine beneficial use support and the results are as follows: 2 of 2 samples exceeded the threshold. CSCI scores were from 0.64079334 to 0.77620822 .
Data Reference: California Stream Condition Index Scores for the 2020 Integrated Report
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in, human, plant or animal, or aquatic life. Compliance with this objective will be determined by use of indicator organisms, analysis of species diversity, population density, growth anomalies, bioassays of appropriate duration, or other appropriate methods as specified by the Regional Board. Region 9 Basin Plan.
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The California Stream Condition Index (CSCI) is a biological scoring tool that helps aquatic resource managers translate complex data about benthic macroinvertebrates found living in a stream into an overall measure of stream health. The CSCI score is calculated by comparing the expected condition with actual (observed) results (Rhen, A.C. et al., 2015). CSCI scores range from 0 (highly degraded) to greater than 1 (equivalent to reference). CSCI scoring of biological condition are as follows (per the scientific paper supporting the development of the CSCI scoring tool): greater than or equal to 0.92 = likely intact condition, 0.91 to 0.80 = possibly altered condition, 0.79 to 0.63 = likely altered condition, less than or equal to 0.62 = very likely altered condition. Sites with scores below 0.79 are considered to have exceeded the water quality objective for the aquatic life beneficial use.  
Guideline Reference: Bioassessment in complex environments: designing an index for consistent meaning in different settings
 
Spatial Representation: Samples were collected from station SMC01049
Temporal Representation: Samples were collected from 6/1/2010 to 7/9/2014.
Environmental Conditions:
QAPP Information: The data was collected under a permit required receiving waters monitoring and reporting program
QAPP Information Reference(s): Quality Assurance Project Plan for Southern California Regional Watershed Monitoring Program Bioassessment, Version 1.0, and Freshwater Bioassessment from Weston Solutions.
 
Line of Evidence (LOE) for Decision ID 125934, Benthic Community Effects
Region 9     
Buena Creek
 
LOE ID: 215777
 
Pollutant: Benthic-Macroinvertebrate Bioassessments
LOE Subgroup: Population/Community Degradation
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: Benthic macroinvertebrate surveys
Data Used to Assess Water Quality: Water Board staff assessed data for SMC04121 to determine beneficial use support and the results are as follows: 1 of 1 samples exceeded the threshold. CSCI scores were from 0.58357835 to 0.58357835 .
Data Reference: California Stream Condition Index Scores for the 2020 Integrated Report
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in, human, plant or animal, or aquatic life. Compliance with this objective will be determined by use of indicator organisms, analysis of species diversity, population density, growth anomalies, bioassays of appropriate duration, or other appropriate methods as specified by the Regional Board. Region 9 Basin Plan.
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The California Stream Condition Index (CSCI) is a biological scoring tool that helps aquatic resource managers translate complex data about benthic macroinvertebrates found living in a stream into an overall measure of stream health. The CSCI score is calculated by comparing the expected condition with actual (observed) results (Rhen, A.C. et al., 2015). CSCI scores range from 0 (highly degraded) to greater than 1 (equivalent to reference). CSCI scoring of biological condition are as follows (per the scientific paper supporting the development of the CSCI scoring tool): greater than or equal to 0.92 = likely intact condition, 0.91 to 0.80 = possibly altered condition, 0.79 to 0.63 = likely altered condition, less than or equal to 0.62 = very likely altered condition. Sites with scores below 0.79 are considered to have exceeded the water quality objective for the aquatic life beneficial use.  
Guideline Reference: Bioassessment in complex environments: designing an index for consistent meaning in different settings
 
Spatial Representation: Samples were collected from station SMC04121
Temporal Representation: Samples were collected from 7/9/2012 to 7/9/2012.
Environmental Conditions:
QAPP Information: The data was collected under a permit required receiving waters monitoring and reporting program
QAPP Information Reference(s): Quality Assurance Project Plan for Southern California Regional Watershed Monitoring Program Bioassessment, Version 1.0, and Freshwater Bioassessment from Weston Solutions.
 
 
DECISION ID
111629
Region 9     
Buena Creek
 
Pollutant: Sulfates
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2006)
Revision Status Revised
Sources: A Source Unknown
Expected TMDL Completion Date: 2033
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

Three lines of evidence are available in the administrative record to assess this pollutant. Six of the six samples exceed the threshold.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Six of six samples exceed the threshold, and this exceeds the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of the available data and information, SWRCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards for the pollutant are not exceeded.
 
 
Line of Evidence (LOE) for Decision ID 111629, Sulfates
Region 9     
Buena Creek
 
LOE ID: 3187
 
Pollutant: Sulfates
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Four of 4 samples exceeded the Basin Plan recommended secondary MCL (SWAMP, 2004).
Data Reference: Placeholder reference 2006 303(d)
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Basin Plan WQO - Title 22 Table 64449-B Secondary Maximum Contaminant Levels of 250 mg/l; Upper Limit- 500 mg/l; Short Term- 1500 mg/l.
Objective/Criterion Reference: Placeholder reference 2006 303(d)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Two Stations at Buena Creek: 33.17225 -117.20887.
Temporal Representation: Samples were collected from March through September of 2002.
Environmental Conditions:
QAPP Information: SWAMP Quality Assurance Plan.
QAPP Information Reference(s):
 
Line of Evidence (LOE) for Decision ID 111629, Sulfates
Region 9     
Buena Creek
 
LOE ID: 146716
 
Pollutant: Sulfates
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Sulfate.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Sulfate water quality threshold in this HSA is 250 mg/L, and this concentration is not to be exceeded more than 10% of the time during any one year period (Basin Plan, Table 3-2).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC04121)
Temporal Representation: The samples were collected between the dates of 2012-07-09 and 2012-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
Line of Evidence (LOE) for Decision ID 111629, Sulfates
Region 9     
Buena Creek
 
LOE ID: 146773
 
Pollutant: Sulfates
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SMC Regional Watershed Monitoring data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality threshold for Sulfate.
Data Reference: Field, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 9.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The Sulfate water quality threshold in this HSA is 250 mg/L, and this concentration is not to be exceeded more than 10% of the time during any one year period (Basin Plan, Table 3-2).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (SMC01049)
Temporal Representation: The samples were collected between the dates of 2014-07-09 and 2014-07-09
Environmental Conditions:
QAPP Information: Weston Solutions, Inc.. 2007. Regional Monitoring of Southern California's Coastal Watersheds., Weston Solutions, Inc.. 2019. Bioassessment Survey of the Stormwater Monitoring Coalition.
QAPP Information Reference(s): Regional Monitoring of Southern California's Coastal Watersheds
QAPP Information Reference(s): Bioassessment Survey of the Stormwater Monitoring Coalition
 
 
DECISION ID
77492
Region 9     
Buena Creek
 
Pollutant: Phosphate
Final Listing Decision: Delist from 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Delist from 303(d) list (TMDL required list)(2016)
Revision Status Original
Reason for Delisting: Flaws in original listing
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: The decision has not changed from the previous listing cycle. No new data were assessed for the current listing cycle. Therefore, the previous conclusion remains unchanged, and is as follows:

Regional Board Conclusion:
This pollutant is being considered for placement on the section 303(d) list under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. A large number of samples exceed the water quality phosphate goal of 0.1 mg/L in stream and flowing waters.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Four of 4 samples exceeded the phosphate water quality objective and this exceeds the allowable frequency listed in Table 3.1 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.



State Board Review and Conclusion:
The original listing in 2006 applied Table 3.1 of the Listing Policy to determine if phosphorus should be listed. Table 3.1 is used for toxicants with a minimum sample requirement of 2 samples. However, Region 9 considers phosphorus a conventional pollutant and as such, Table 3.2 should have been applied with a minimum requirement of 5 samples.

There are only 4 samples in the line of evidence and this is insufficient to place the water body-pollutant combination on the section 303(d) list.

Furthermore, the line of evidence used to list this water body was based on phosphorus data and not phosphate data. The appropriate decision should have been for phosphorus.

State Board staff re-evaluated the original listing and recommends to Delist phosphate. Also, in order to correctly track these phosphorus data, these same data have been reassessed under the correct pollutant name "phosphorus" with a Do Not List decision. The revised recommendation for delisting phosphate is as follows:

This pollutant is being considered for removal from the section 303(d) list under section 4 of the Listing Policy. Under this section an existing listing may be removed if the listing was based on faulty data and it is demonstrated that the listing would not have occurred in the absence of such faulty data.

One line of evidence is available in the administrative record to assess this pollutant. Four of 4 samples exceed the water quality goal of 0.1 mg/L for phosphorus in streams and flowing waters.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of removing this water segment-pollutant combination from the section 303(d) list.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Four of 4 samples exceeded the basin plan water quality goal and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy. This pollutant should not have been listed in 2006.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: This is a decision previously approved by the State Water Resources Control Board and the USEPA. No new data were assessed by the Regional Board for the current cycle. The decision has not changed.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 77492, Phosphate
Region 9     
Buena Creek
 
LOE ID: 3188
 
Pollutant: Phosphate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Four water samples, four samples exceeding the basin plan goal (SWAMP, 2004).
Data Reference: Placeholder reference 2006 303(d)
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain biostimulatory substances in concentrations that promote aquatic growth to the extent that such growth causes nuisances or adversely affects beneficial uses. Water Quality Control Plan phosphate goal of 0.1 mg/L in stream and flowing waters.
Objective/Criterion Reference: Placeholder reference 2006 303(d)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: One Station at Buena Creek: 33.17225 -117.20887.
Temporal Representation: Samples were collected from March through September of 2002.
Environmental Conditions: Buena Creek 904.32.
QAPP Information: SWAMP Quality Assurance Plan.
QAPP Information Reference(s):
 
 
DECISION ID
68907
Region 9     
Buena Creek
 
Pollutant: Nitrate and Nitrite
Final Listing Decision: Do Not Delist from 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not Delist from 303(d) list (TMDL required list)(2016)
Revision Status Original
Sources: A Source Unknown
Expected TMDL Completion Date: 2019
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for removal from the CWA section 303(d) List under section 4.1 of the Listing Policy. Under this section a single line of evidence is necessary to assess listing status.

One lines of evidence are available in the administrative record to assess pollutant. Five of 5 samples exceed the criteria.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against removing this water segment-pollutant combination from the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Five of 5 samples exceed the criteria and this exceeds the allowable frequency listed in Table 4.1 of the Listing Policy.
4. Pursuant to section 4.11 of the Listing Policy, no additional data and information are available indicating that standards are met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be removed from the section 303(d) list because applicable water quality standards for the pollutant are being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 68907, Nitrate and Nitrite
Region 9     
Buena Creek
 
LOE ID: 3185
 
Pollutant: Nitrate and Nitrite
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Four of 4 samples exceeded the MCLs (SWAMP, 2004).
Data Reference: Placeholder reference 2006 303(d)
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters designated for use as domestic or municipal supply shall not contain concentrations of nitrate and nitrite as nitrogen in excess of Maximum Contaminant Levels (MCL) set forth in Title 22 of the CCR, Table 64431-A of section 64431.
Objective/Criterion Reference: Placeholder reference 2006 303(d)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: One sample site at Buena Creek: 33.17225 - 117.20887.
Temporal Representation: Samples were collected from March through September of 2002.
Environmental Conditions: Buena Creek 904.32.
QAPP Information: SWAMP Quality Assurance Plan
QAPP Information Reference(s):
 
Line of Evidence (LOE) for Decision ID 68907, Nitrate and Nitrite
Region 9     
Buena Creek
 
LOE ID: 73092
 
Pollutant: Nitrate/Nitrite (Nitrite + Nitrate as N)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceed the criterion for Nitrate/Nitrite as N.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The California Maximum Contaminant Level for nitrate + nitrite (as N) is 10.0 mg/L (Title 22 of the California Code of Regulations).
Objective/Criterion Reference: Maximum Contaminant Levels for organic and inorganic chemicals. CCR Title 22
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected on a single day 9/3/2003.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
81145
Region 9     
Buena Creek
 
Pollutant: Chlorpyrifos
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 5 samples exceed the criteria for MUN and 0 of 0 samples exceed the criteria for WARM.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 5 samples exceed the criteria for MUN and 0 of 0 samples exceed the criteria for WARM and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 81145, Chlorpyrifos
Region 9     
Buena Creek
 
LOE ID: 73083
 
Pollutant: Chlorpyrifos
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 0
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 0 samples exceed the criterion for Chlorpyrifos.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The freshwater criterion continuous concentration to protect aquatic organisms is 0.015 ug/L (Siepmann and Finlayson 2000).
Guideline Reference: Water quality criteria for diazinon and chlorpyrifos. Administrative Report 00-3. Rancho Cordova, CA: Pesticide Investigations Unit, Office of Spills and Response. CA Department of Fish and Game (with minor corrections to significant figures as described in Beaulaurier et al., 2005).
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 81145, Chlorpyrifos
Region 9     
Buena Creek
 
LOE ID: 77986
 
Pollutant: Chlorpyrifos
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 5 samples exceed the criterion for Chlorpyrifos.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The USEPA drinking water health advisory for chlorpyrifos is 2.1 µg/L.
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
76687
Region 9     
Buena Creek
 
Pollutant: Diazinon
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 5 samples exceed the criteria for MUN and 0 of 5 samples exceed the criteria for WARM.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 5 samples exceed the criteria for MUN and 0 of 5 samples exceed the criteria for WARM and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 76687, Diazinon
Region 9     
Buena Creek
 
LOE ID: 73086
 
Pollutant: Diazinon
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 5 samples exceed the criterion for Diazinon.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The freshwater chronic value for diazinon is 0.1 ug/L, expressed as a continuous concentration (Finlayson, 2004).
Guideline Reference: Water quality for diazinon. Memorandum to J. Karkoski, Central Valley RWQCB. Rancho Cordova, CA: Pesticide Investigation Unit, CA Department of Fish and Game
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 76687, Diazinon
Region 9     
Buena Creek
 
LOE ID: 77987
 
Pollutant: Diazinon
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 5 samples exceed the criterion for Diazinon.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The USEPA drinking water health advisory for diazinon is 1.4 µg/L.
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
77911
Region 9     
Buena Creek
 
Pollutant: Malathion
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 5 samples exceed the criteria for MUN and 0 of 5 samples exceed the criteria for WARM.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 5 samples exceed the criteria for MUN and 0 of 5 samples exceed the criteria for WARM and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 77911, Malathion
Region 9     
Buena Creek
 
LOE ID: 73091
 
Pollutant: Malathion
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Warm Freshwater Habitat
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 5 samples exceed the criterion for Malathion.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The USEPA national ambient water quality criteria for freshwater aquatic life instantaneous maximum for malathion is 0.1 µg/L.
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 77911, Malathion
Region 9     
Buena Creek
 
LOE ID: 77988
 
Pollutant: Malathion
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 5 samples exceed the criterion for Malathion.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: The USEPA drinking water health advisory for malathion is 100 µg/L.
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 9/28/2005-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
81196
Region 9     
Buena Creek
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.

One lines of evidence are available in the administrative record to assess this pollutant. Zero of 1 sample exceeds the criteria.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 1 sample exceeds the criteria and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 81196, Nitrogen, ammonia (Total Ammonia)
Region 9     
Buena Creek
 
LOE ID: 73080
 
Pollutant: Nitrogen, ammonia (Total Ammonia)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceed the criterion for Ammonia As N, Total.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Basin Plan: No individual chemical or combination of chemicals shall be present in concentrations that adversely affect beneficial uses (Water Quality Control Plan, San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: EPA's Lifetime Health advisory level for total ammonia is 30.0 mg/L as stated on page 8 of the 2006 edition of the drinking water standards and health advisories. This Advisory Level is defined as "the concentration of a chemical in drinking water that is not expected to cause any adverse noncarcinogenic effects for up to ten days of exposure."
Guideline Reference: 2006 edition of the drinking water standards and health advisories. EPA 822-R-03-013
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected on a single day 6/30/2003.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
 
DECISION ID
68398
Region 9     
Buena Creek
 
Pollutant: DDT (Dichlorodiphenyltrichloroethane)
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Sources: A Source Unknown
Expected TMDL Completion Date: 2019
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the section 303(d) list under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. A large number of samples exceed the California Toxic Rule: Human Health carcinogenic risk for consumption of water & organisms of 0.00059 µg/L.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Four of 4 samples exceeded the CTR DDT criterion and this exceeds the allowable frequency listed in Table 3.1 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: This is a decision previously approved by the State Water Resources Control Board and the USEPA. No new data were assessed by the Regional Board for the current cycle. The decision has not changed.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 68398, DDT (Dichlorodiphenyltrichloroethane)
Region 9     
Buena Creek
 
LOE ID: 3186
 
Pollutant: DDT (Dichlorodiphenyltrichloroethane)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 4
Number of Exceedances: 4
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Four of 4 samples exceeded the CTR criterion (SWAMP, 2004).
Data Reference: Placeholder reference 2006 303(d)
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: No individual pesticide or combination of pesticides shall be present in the water column, sediments or biota at concentration(s) that adversely affect beneficial uses.

California Toxic Rule: Human Health carcinogenic risk for consumption of water & organisms, 0.00059 μg/L.
Objective/Criterion Reference: Placeholder reference 2006 303(d)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: One sample site in Buena Creek at 33.17225 - 117.20887.
Temporal Representation: Samples were collected from March through September of 2002.
Environmental Conditions: Buena Creek 904.32
QAPP Information: SWAMP Quality Assurance Plan.
QAPP Information Reference(s):
 
 
DECISION ID
86639
Region 9     
Buena Creek
 
Pollutant: Indicator Bacteria
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Sources: A Source Unknown
Expected TMDL Completion Date: 2029
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

Three lines of evidence are available in the administrative record to assess this pollutant. Data from 2003 to 2009 show that 7 of 8 and 6 of 8 single samples exceed the water quality objectives for single sample maximums of enterococcus and fecal coliform for the protection of REC-1, and 3 of 8 samples exceeded the evaluation guideline for Total Coliform.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Data from 2003 to 2009 show that 7 of 8 and 6 of 8 single samples exceed the water quality objectives for single sample maximums of enterococcus and fecal coliform for the protection of REC-1 and this exceeds the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 86639, Indicator Bacteria
Region 9     
Buena Creek
 
LOE ID: 73088
 
Pollutant: Fecal Coliform
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 8
Number of Exceedances: 6
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 6 of 8 samples exceed the criterion for Coliform, Fecal.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: In waters designated for water contact recreation (REC I), the fecal coliform concentration shall not exceed 400 MPN/100 ml.
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 6/30/2003-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 86639, Indicator Bacteria
Region 9     
Buena Creek
 
LOE ID: 73094
 
Pollutant: Total Coliform
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 8
Number of Exceedances: 3
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 3 of 8 samples exceed the criterion for Coliform, Total.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: All waters shall be maintained free of toxicsubstances in concentrations which are toxic to,or which produce detrimental physiologicalresponses in human, plant, animal, or indigenousaquatic life (Basin Plan).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline: In waters designated for water contact recreation (REC I), the total coliform concentration shall not exceed 10000 MPN/100 ml (CDPH 2006).
Guideline Reference: Draft Guidance for Fresh Water Beaches. Last Update: May 8, 2006. Initial Draft: November 1997. California Department of Public Health.
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 6/30/2003-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.
 
Line of Evidence (LOE) for Decision ID 86639, Indicator Bacteria
Region 9     
Buena Creek
 
LOE ID: 73087
 
Pollutant: Enterococcus
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 8
Number of Exceedances: 7
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed County of San Diego data for Buena Creek to determine beneficial use support and results are as follows: 7 of 8 samples exceed the criterion for Enterococci.
Data Reference: Data for Metals, Nutrients, Inorganics, Organics, Pathogens, and Pesticides from the County of San Diego, 2003-2009.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Samples shall not exceed 61 organisms per 100 ml for enterococcus in waters designated for REC I beneficial use (Water Quality Control Plan for the San Diego Basin).
Objective/Criterion Reference: Water Quality Control Plan for the San Diego Basin
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Data for this line of evidence for Buena Creek was collected at 1 monitoring site [ Buena Creek @ Robelini Drive]
Temporal Representation: Data was collected over the time period 6/30/2003-6/10/2009.
Environmental Conditions: Staff is not aware of any special conditions that might affect interpretation of the data.
QAPP Information: The Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8 was followed.
QAPP Information Reference(s): Quality Assurance Project Plan from the Truesdail Laboratories, Rev. 12, Enviromatrix Analytical and Dry Weather Monitoring Program Rev. 8.